Drive Data Sheets

From Linux Raid Wiki
(Difference between revisions)
Jump to: navigation, search
m (Hitachi HGST UltraStar)
(WDC WD1003FBYX-01Y7B1 (1TB))
(7 intermediate revisions by one user not shown)
Line 9: Line 9:
 
= Hitachi Drives =
 
= Hitachi Drives =
 
== Raid drives ==
 
== Raid drives ==
 +
=== Hitachi/HGST Ultrastar 7K4000 ===
 +
==== HGST HUS724020ALA640 (2TB) ====
 +
<pre>
 +
smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.9.0-4-amd64] (local build)
 +
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
 +
 +
=== START OF INFORMATION SECTION ===
 +
Model Family:    Hitachi/HGST Ultrastar 7K4000
 +
Device Model:    HGST HUS724020ALA640
 +
Serial Number:    PN1138P2GJ8MYH
 +
LU WWN Device Id: 5 000cca 24bc76662
 +
Firmware Version: MF6OAA70
 +
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
 +
Sector Size:      512 bytes logical/physical
 +
Rotation Rate:    7200 rpm
 +
Form Factor:      3.5 inches
 +
Device is:        In smartctl database [for details use: -P show]
 +
ATA Version is:  ATA8-ACS T13/1699-D revision 4
 +
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
 +
Local Time is:    Tue Oct 10 10:31:21 2017 UTC
 +
SMART support is: Available - device has SMART capability.
 +
SMART support is: Enabled
 +
AAM feature is:  Unavailable
 +
APM feature is:  Disabled
 +
Rd look-ahead is: Enabled
 +
Write cache is:  Enabled
 +
ATA Security is:  Disabled, frozen [SEC2]
 +
Wt Cache Reorder: Enabled
 +
 +
=== START OF READ SMART DATA SECTION ===
 +
SMART overall-health self-assessment test result: PASSED
 +
 +
General SMART Values:
 +
Offline data collection status:  (0x82) Offline data collection activity
 +
was completed without error.
 +
Auto Offline Data Collection: Enabled.
 +
Self-test execution status:      (  41) The self-test routine was interrupted
 +
by the host with a hard or soft reset.
 +
Total time to complete Offline
 +
data collection: (  28) seconds.
 +
Offline data collection
 +
capabilities: (0x5b) SMART execute Offline immediate.
 +
Auto Offline data collection on/off support.
 +
Suspend Offline collection upon new
 +
command.
 +
Offline surface scan supported.
 +
Self-test supported.
 +
No Conveyance Self-test supported.
 +
Selective Self-test supported.
 +
SMART capabilities:            (0x0003) Saves SMART data before entering
 +
power-saving mode.
 +
Supports SMART auto save timer.
 +
Error logging capability:        (0x01) Error logging supported.
 +
General Purpose Logging supported.
 +
Short self-test routine
 +
recommended polling time: (  1) minutes.
 +
Extended self-test routine
 +
recommended polling time: ( 328) minutes.
 +
SCT capabilities:       (0x003d) SCT Status supported.
 +
SCT Error Recovery Control supported.
 +
SCT Feature Control supported.
 +
SCT Data Table supported.
 +
 +
SMART Attributes Data Structure revision number: 16
 +
Vendor Specific SMART Attributes with Thresholds:
 +
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
 +
  1 Raw_Read_Error_Rate    PO-R--  100  100  016    -    0
 +
  2 Throughput_Performance  P-S---  137  137  054    -    78
 +
  3 Spin_Up_Time            POS---  149  149  024    -    434 (Average 402)
 +
  4 Start_Stop_Count        -O--C-  100  100  000    -    18
 +
  5 Reallocated_Sector_Ct  PO--CK  100  100  005    -    0
 +
  7 Seek_Error_Rate        PO-R--  100  100  067    -    0
 +
  8 Seek_Time_Performance  P-S---  142  142  020    -    25
 +
  9 Power_On_Hours          -O--C-  098  098  000    -    15240
 +
10 Spin_Retry_Count        PO--C-  100  100  060    -    0
 +
12 Power_Cycle_Count      -O--CK  100  100  000    -    18
 +
192 Power-Off_Retract_Count -O--CK  100  100  000    -    403
 +
193 Load_Cycle_Count        -O--C-  100  100  000    -    403
 +
194 Temperature_Celsius    -O----  166  166  000    -    36 (Min/Max 23/49)
 +
196 Reallocated_Event_Count -O--CK  100  100  000    -    0
 +
197 Current_Pending_Sector  -O---K  100  100  000    -    0
 +
198 Offline_Uncorrectable  ---R--  100  100  000    -    0
 +
199 UDMA_CRC_Error_Count    -O-R--  200  200  000    -    0
 +
                            ||||||_ K auto-keep
 +
                            |||||__ C event count
 +
                            ||||___ R error rate
 +
                            |||____ S speed/performance
 +
                            ||_____ O updated online
 +
                            |______ P prefailure warning
 +
 +
General Purpose Log Directory Version 1
 +
SMART          Log Directory Version 1 [multi-sector log support]
 +
Address    Access  R/W  Size  Description
 +
0x00      GPL,SL  R/O      1  Log Directory
 +
0x01          SL  R/O      1  Summary SMART error log
 +
0x03      GPL    R/O      1  Ext. Comprehensive SMART error log
 +
0x04      GPL    R/O      7  Device Statistics log
 +
0x06          SL  R/O      1  SMART self-test log
 +
0x07      GPL    R/O      1  Extended self-test log
 +
0x08      GPL    R/O      2  Power Conditions log
 +
0x09          SL  R/W      1  Selective self-test log
 +
0x10      GPL    R/O      1  SATA NCQ Queued Error log
 +
0x11      GPL    R/O      1  SATA Phy Event Counters log
 +
0x20      GPL    R/O      1  Streaming performance log [OBS-8]
 +
0x21      GPL    R/O      1  Write stream error log
 +
0x22      GPL    R/O      1  Read stream error log
 +
0x80-0x9f  GPL,SL  R/W    16  Host vendor specific log
 +
0xe0      GPL,SL  R/W      1  SCT Command/Status
 +
0xe1      GPL,SL  R/W      1  SCT Data Transfer
 +
 +
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
 +
No Errors Logged
 +
 +
SMART Extended Self-test Log Version: 1 (1 sectors)
 +
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
 +
# 1  Extended offline    Interrupted (host reset)      90%    14493        -
 +
 +
SMART Selective self-test log data structure revision number 1
 +
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
 +
    1        0        0  Not_testing
 +
    2        0        0  Not_testing
 +
    3        0        0  Not_testing
 +
    4        0        0  Not_testing
 +
    5        0        0  Not_testing
 +
Selective self-test flags (0x0):
 +
  After scanning selected spans, do NOT read-scan remainder of disk.
 +
If Selective self-test is pending on power-up, resume after 0 minute delay.
 +
 +
SCT Status Version:                  3
 +
SCT Version (vendor specific):      256 (0x0100)
 +
SCT Support Level:                  1
 +
Device State:                        Active (0)
 +
Current Temperature:                    36 Celsius
 +
Power Cycle Min/Max Temperature:    35/40 Celsius
 +
Lifetime    Min/Max Temperature:    23/49 Celsius
 +
Under/Over Temperature Limit Count:  0/0
 +
 +
SCT Temperature History Version:    2
 +
Temperature Sampling Period:        1 minute
 +
Temperature Logging Interval:        1 minute
 +
Min/Max recommended Temperature:      0/60 Celsius
 +
Min/Max Temperature Limit:          -40/70 Celsius
 +
Temperature History Size (Index):    128 (96)
 +
 +
Index    Estimated Time  Temperature Celsius
 +
  97    2017-10-10 08:24    36  *****************
 +
...    ..(126 skipped).    ..  *****************
 +
  96    2017-10-10 10:31    36  *****************
 +
 +
SCT Error Recovery Control:
 +
          Read: Disabled
 +
          Write: Disabled
 +
 +
Device Statistics (GP Log 0x04)
 +
Page  Offset Size        Value Flags Description
 +
0x01  =====  =              =  ===  == General Statistics (rev 2) ==
 +
0x01  0x008  4              18  ---  Lifetime Power-On Resets
 +
0x01  0x018  6    353645484537  ---  Logical Sectors Written
 +
0x01  0x020  6    13505157115  ---  Number of Write Commands
 +
0x01  0x028  6    319592434652  ---  Logical Sectors Read
 +
0x01  0x030  6      2292219761  ---  Number of Read Commands
 +
0x03  =====  =              =  ===  == Rotating Media Statistics (rev 1) ==
 +
0x03  0x008  4          15238  ---  Spindle Motor Power-on Hours
 +
0x03  0x010  4          15238  ---  Head Flying Hours
 +
0x03  0x018  4            403  ---  Head Load Events
 +
0x03  0x020  4              0  ---  Number of Reallocated Logical Sectors
 +
0x03  0x028  4              2  ---  Read Recovery Attempts
 +
0x03  0x030  4              0  ---  Number of Mechanical Start Failures
 +
0x04  =====  =              =  ===  == General Errors Statistics (rev 1) ==
 +
0x04  0x008  4              0  ---  Number of Reported Uncorrectable Errors
 +
0x04  0x010  4              0  ---  Resets Between Cmd Acceptance and Completion
 +
0x05  =====  =              =  ===  == Temperature Statistics (rev 1) ==
 +
0x05  0x008  1              36  ---  Current Temperature
 +
0x05  0x010  1              36  N--  Average Short Term Temperature
 +
0x05  0x018  1              37  N--  Average Long Term Temperature
 +
0x05  0x020  1              49  ---  Highest Temperature
 +
0x05  0x028  1              23  ---  Lowest Temperature
 +
0x05  0x030  1              44  N--  Highest Average Short Term Temperature
 +
0x05  0x038  1              25  N--  Lowest Average Short Term Temperature
 +
0x05  0x040  1              40  N--  Highest Average Long Term Temperature
 +
0x05  0x048  1              25  N--  Lowest Average Long Term Temperature
 +
0x05  0x050  4              0  ---  Time in Over-Temperature
 +
0x05  0x058  1              60  ---  Specified Maximum Operating Temperature
 +
0x05  0x060  4              0  ---  Time in Under-Temperature
 +
0x05  0x068  1              0  ---  Specified Minimum Operating Temperature
 +
0x06  =====  =              =  ===  == Transport Statistics (rev 1) ==
 +
0x06  0x008  4            234  ---  Number of Hardware Resets
 +
0x06  0x010  4            209  ---  Number of ASR Events
 +
0x06  0x018  4              0  ---  Number of Interface CRC Errors
 +
                                |||_ C monitored condition met
 +
                                ||__ D supports DSN
 +
                                |___ N normalized value
 +
 +
SATA Phy Event Counters (GP Log 0x11)
 +
ID      Size    Value  Description
 +
0x0001  2            0  Command failed due to ICRC error
 +
 +
</pre>
 +
==== HGST HUS726060ALE610 (6TB) ====
 +
<pre>
 +
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
 +
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
 +
 +
=== START OF INFORMATION SECTION ===
 +
Device Model:    HGST HUS726060ALE610
 +
Serial Number:    NAHSHAAX
 +
LU WWN Device Id: 5 000cca 242d8c599
 +
Firmware Version: APGNT7J0
 +
User Capacity:    6,001,175,126,016 bytes [6.00 TB]
 +
Sector Sizes:    512 bytes logical, 4096 bytes physical
 +
Rotation Rate:    7200 rpm
 +
Form Factor:      3.5 inches
 +
Device is:        Not in smartctl database [for details use: -P showall]
 +
ATA Version is:  ACS-2, ATA8-ACS T13/1699-D revision 4
 +
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
 +
Local Time is:    Tue Oct 10 12:14:03 2017 CEST
 +
SMART support is: Available - device has SMART capability.
 +
SMART support is: Enabled
 +
AAM feature is:  Unavailable
 +
APM level is:    254 (maximum performance)
 +
Rd look-ahead is: Enabled
 +
Write cache is:  Enabled
 +
ATA Security is:  Disabled, NOT FROZEN [SEC1]
 +
Wt Cache Reorder: Enabled
 +
 +
=== START OF READ SMART DATA SECTION ===
 +
SMART overall-health self-assessment test result: PASSED
 +
 +
General SMART Values:
 +
Offline data collection status:  (0x82) Offline data collection activity
 +
was completed without error.
 +
Auto Offline Data Collection: Enabled.
 +
Self-test execution status:      (  0) The previous self-test routine completed
 +
without error or no self-test has ever
 +
been run.
 +
Total time to complete Offline
 +
data collection: (  113) seconds.
 +
Offline data collection
 +
capabilities: (0x5b) SMART execute Offline immediate.
 +
Auto Offline data collection on/off support.
 +
Suspend Offline collection upon new
 +
command.
 +
Offline surface scan supported.
 +
Self-test supported.
 +
No Conveyance Self-test supported.
 +
Selective Self-test supported.
 +
SMART capabilities:            (0x0003) Saves SMART data before entering
 +
power-saving mode.
 +
Supports SMART auto save timer.
 +
Error logging capability:        (0x01) Error logging supported.
 +
General Purpose Logging supported.
 +
Short self-test routine
 +
recommended polling time: (  2) minutes.
 +
Extended self-test routine
 +
recommended polling time: ( 752) minutes.
 +
SCT capabilities:       (0x003d) SCT Status supported.
 +
SCT Error Recovery Control supported.
 +
SCT Feature Control supported.
 +
SCT Data Table supported.
 +
 +
SMART Attributes Data Structure revision number: 16
 +
Vendor Specific SMART Attributes with Thresholds:
 +
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
 +
  1 Raw_Read_Error_Rate    PO-R--  100  100  016    -    0
 +
  2 Throughput_Performance  P-S---  138  138  054    -    100
 +
  3 Spin_Up_Time            POS---  100  100  024    -    0
 +
  4 Start_Stop_Count        -O--C-  100  100  000    -    6
 +
  5 Reallocated_Sector_Ct  PO--CK  100  100  005    -    0
 +
  7 Seek_Error_Rate        PO-R--  100  100  067    -    0
 +
  8 Seek_Time_Performance  P-S---  136  136  020    -    16
 +
  9 Power_On_Hours          -O--C-  098  098  000    -    16085
 +
10 Spin_Retry_Count        PO--C-  100  100  060    -    0
 +
12 Power_Cycle_Count      -O--CK  100  100  000    -    6
 +
192 Power-Off_Retract_Count -O--CK  100  100  000    -    672
 +
193 Load_Cycle_Count        -O--C-  100  100  000    -    672
 +
194 Temperature_Celsius    -O----  200  200  000    -    30 (Min/Max 19/36)
 +
196 Reallocated_Event_Count -O--CK  100  100  000    -    0
 +
197 Current_Pending_Sector  -O---K  100  100  000    -    0
 +
198 Offline_Uncorrectable  ---R--  100  100  000    -    0
 +
199 UDMA_CRC_Error_Count    -O-R--  200  200  000    -    0
 +
                            ||||||_ K auto-keep
 +
                            |||||__ C event count
 +
                            ||||___ R error rate
 +
                            |||____ S speed/performance
 +
                            ||_____ O updated online
 +
                            |______ P prefailure warning
 +
 +
General Purpose Log Directory Version 1
 +
SMART          Log Directory Version 1 [multi-sector log support]
 +
Address    Access  R/W  Size  Description
 +
0x00      GPL,SL  R/O      1  Log Directory
 +
0x01          SL  R/O      1  Summary SMART error log
 +
0x02          SL  R/O      1  Comprehensive SMART error log
 +
0x03      GPL    R/O      1  Ext. Comprehensive SMART error log
 +
0x04      GPL,SL  R/O      8  Device Statistics log
 +
0x06          SL  R/O      1  SMART self-test log
 +
0x07      GPL    R/O      1  Extended self-test log
 +
0x08      GPL    R/O      2  Power Conditions log
 +
0x09          SL  R/W      1  Selective self-test log
 +
0x10      GPL    R/O      1  SATA NCQ Queued Error log
 +
0x11      GPL    R/O      1  SATA Phy Event Counters log
 +
0x12      GPL    R/O      1  SATA NCQ NON-DATA log
 +
0x15      GPL,SL  R/W      1  SATA Rebuild Assist log
 +
0x21      GPL    R/O      1  Write stream error log
 +
0x22      GPL    R/O      1  Read stream error log
 +
0x24      GPL    R/O    256  Current Device Internal Status Data log
 +
0x25      GPL    R/O    256  Saved Device Internal Status Data log
 +
0x30      GPL,SL  R/O      9  IDENTIFY DEVICE data log
 +
0x80-0x9f  GPL,SL  R/W    16  Host vendor specific log
 +
0xe0      GPL,SL  R/W      1  SCT Command/Status
 +
0xe1      GPL,SL  R/W      1  SCT Data Transfer
 +
 +
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
 +
No Errors Logged
 +
 +
SMART Extended Self-test Log Version: 1 (1 sectors)
 +
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
 +
# 1  Extended offline    Completed without error      00%    15954        -
 +
 +
SMART Selective self-test log data structure revision number 1
 +
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
 +
    1        0        0  Not_testing
 +
    2        0        0  Not_testing
 +
    3        0        0  Not_testing
 +
    4        0        0  Not_testing
 +
    5        0        0  Not_testing
 +
Selective self-test flags (0x0):
 +
  After scanning selected spans, do NOT read-scan remainder of disk.
 +
If Selective self-test is pending on power-up, resume after 0 minute delay.
 +
 +
SCT Status Version:                  3
 +
SCT Version (vendor specific):      256 (0x0100)
 +
SCT Support Level:                  1
 +
Device State:                        Active (0)
 +
Current Temperature:                    30 Celsius
 +
Power Cycle Min/Max Temperature:    25/33 Celsius
 +
Lifetime    Min/Max Temperature:    19/36 Celsius
 +
Under/Over Temperature Limit Count:  0/0
 +
 +
SCT Temperature History Version:    2
 +
Temperature Sampling Period:        1 minute
 +
Temperature Logging Interval:        1 minute
 +
Min/Max recommended Temperature:      0/60 Celsius
 +
Min/Max Temperature Limit:          -40/70 Celsius
 +
Temperature History Size (Index):    128 (79)
 +
 +
Index    Estimated Time  Temperature Celsius
 +
  80    2017-10-10 10:07    30  ***********
 +
 +
SCT Error Recovery Control:
 +
          Read: Disabled
 +
          Write: Disabled
 +
 +
Device Statistics (GP Log 0x04)
 +
Page Offset Size        Value  Description
 +
  1  =====  =                =  == General Statistics (rev 2) ==
 +
  1  0x008  4                6  Lifetime Power-On Resets
 +
  1  0x018  6      6837083432  Logical Sectors Written
 +
  1  0x020  6        18033121  Number of Write Commands
 +
  1  0x028  6    103037210207  Logical Sectors Read
 +
  1  0x030  6        84755469  Number of Read Commands
 +
  1  0x038  6      57908116650  Date and Time TimeStamp
 +
  3  =====  =                =  == Rotating Media Statistics (rev 1) ==
 +
  3  0x008  4            16065  Spindle Motor Power-on Hours
 +
  3  0x010  4            16065  Head Flying Hours
 +
  3  0x018  4              672  Head Load Events
 +
  3  0x020  4                0  Number of Reallocated Logical Sectors
 +
  3  0x028  4          1904036  Read Recovery Attempts
 +
  3  0x030  4                0  Number of Mechanical Start Failures
 +
  4  =====  =                =  == General Errors Statistics (rev 1) ==
 +
  4  0x008  4                0  Number of Reported Uncorrectable Errors
 +
  4  0x010  4                0  Resets Between Cmd Acceptance and Completion
 +
  5  =====  =                =  == Temperature Statistics (rev 1) ==
 +
  5  0x008  1              30  Current Temperature
 +
  5  0x010  1              30~ Average Short Term Temperature
 +
  5  0x018  1              29~ Average Long Term Temperature
 +
  5  0x020  1              36  Highest Temperature
 +
  5  0x028  1              19  Lowest Temperature
 +
  5  0x030  1              34~ Highest Average Short Term Temperature
 +
  5  0x038  1              25~ Lowest Average Short Term Temperature
 +
  5  0x040  1              32~ Highest Average Long Term Temperature
 +
  5  0x048  1              25~ Lowest Average Long Term Temperature
 +
  5  0x050  4                0  Time in Over-Temperature
 +
  5  0x058  1              60  Specified Maximum Operating Temperature
 +
  5  0x060  4                0  Time in Under-Temperature
 +
  5  0x068  1                0  Specified Minimum Operating Temperature
 +
  6  =====  =                =  == Transport Statistics (rev 1) ==
 +
  6  0x008  4                7  Number of Hardware Resets
 +
  6  0x010  4                0  Number of ASR Events
 +
  6  0x018  4                0  Number of Interface CRC Errors
 +
                              |_ ~ normalized value
 +
 +
SATA Phy Event Counters (GP Log 0x11)
 +
ID      Size    Value  Description
 +
0x0001  2            0  Command failed due to ICRC error
 +
 +
</pre>
 +
 
=== Hitachi UltraStar ===
 
=== Hitachi UltraStar ===
 
==== HUS726020ALA610 2TB ====
 
==== HUS726020ALA610 2TB ====
Line 204: Line 602:
 
   6  0x008  4              14  Number of Hardware Resets
 
   6  0x008  4              14  Number of Hardware Resets
 
   6  0x010  4              22  Number of ASR Events
 
   6  0x010  4              22  Number of ASR Events
 +
  6  0x018  4                0  Number of Interface CRC Errors
 +
                              |_ ~ normalized value
 +
 +
SATA Phy Event Counters (GP Log 0x11)
 +
ID      Size    Value  Description
 +
0x0001  2            0  Command failed due to ICRC error
 +
 +
</pre>
 +
 +
=== Hitachi Ultrastar 7K3000 ===
 +
==== Hitachi HUA723030ALA640 3TB ====
 +
<pre>
 +
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
 +
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
 +
 +
=== START OF INFORMATION SECTION ===
 +
Model Family:    Hitachi Ultrastar 7K3000
 +
Device Model:    Hitachi HUA723030ALA640
 +
Serial Number:    MK0331YHH2R1BA
 +
LU WWN Device Id: 5 000cca 225cf52ff
 +
Firmware Version: MKAOA800
 +
User Capacity:    3,000,592,982,016 bytes [3.00 TB]
 +
Sector Size:      512 bytes logical/physical
 +
Rotation Rate:    7200 rpm
 +
Form Factor:      3.5 inches
 +
Device is:        In smartctl database [for details use: -P show]
 +
ATA Version is:  ATA8-ACS T13/1699-D revision 4
 +
SATA Version is:  SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
 +
Local Time is:    Tue Oct 10 11:12:40 2017 UTC
 +
SMART support is: Available - device has SMART capability.
 +
SMART support is: Enabled
 +
AAM feature is:  Unavailable
 +
APM feature is:  Disabled
 +
Rd look-ahead is: Enabled
 +
Write cache is:  Enabled
 +
ATA Security is:  Disabled, NOT FROZEN [SEC1]
 +
Wt Cache Reorder: Enabled
 +
 +
=== START OF READ SMART DATA SECTION ===
 +
SMART overall-health self-assessment test result: PASSED
 +
 +
General SMART Values:
 +
Offline data collection status:  (0x84) Offline data collection activity
 +
was suspended by an interrupting command from host.
 +
Auto Offline Data Collection: Enabled.
 +
Self-test execution status:      (  0) The previous self-test routine completed
 +
without error or no self-test has ever
 +
been run.
 +
Total time to complete Offline
 +
data collection: (29746) seconds.
 +
Offline data collection
 +
capabilities: (0x5b) SMART execute Offline immediate.
 +
Auto Offline data collection on/off support.
 +
Suspend Offline collection upon new
 +
command.
 +
Offline surface scan supported.
 +
Self-test supported.
 +
No Conveyance Self-test supported.
 +
Selective Self-test supported.
 +
SMART capabilities:            (0x0003) Saves SMART data before entering
 +
power-saving mode.
 +
Supports SMART auto save timer.
 +
Error logging capability:        (0x01) Error logging supported.
 +
General Purpose Logging supported.
 +
Short self-test routine
 +
recommended polling time: (  1) minutes.
 +
Extended self-test routine
 +
recommended polling time: ( 496) minutes.
 +
SCT capabilities:       (0x003d) SCT Status supported.
 +
SCT Error Recovery Control supported.
 +
SCT Feature Control supported.
 +
SCT Data Table supported.
 +
 +
SMART Attributes Data Structure revision number: 16
 +
Vendor Specific SMART Attributes with Thresholds:
 +
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
 +
  1 Raw_Read_Error_Rate    PO-R--  100  100  016    -    0
 +
  2 Throughput_Performance  P-S---  135  135  054    -    85
 +
  3 Spin_Up_Time            POS---  100  100  024    -    506
 +
  4 Start_Stop_Count        -O--C-  100  100  000    -    14
 +
  5 Reallocated_Sector_Ct  PO--CK  100  100  005    -    0
 +
  7 Seek_Error_Rate        PO-R--  100  100  067    -    0
 +
  8 Seek_Time_Performance  P-S---  138  138  020    -    25
 +
  9 Power_On_Hours          -O--C-  093  093  000    -    50018
 +
10 Spin_Retry_Count        PO--C-  100  100  060    -    0
 +
12 Power_Cycle_Count      -O--CK  100  100  000    -    14
 +
192 Power-Off_Retract_Count -O--CK  099  099  000    -    1512
 +
193 Load_Cycle_Count        -O--C-  099  099  000    -    1512
 +
194 Temperature_Celsius    -O----  222  222  000    -    27 (Min/Max 17/41)
 +
196 Reallocated_Event_Count -O--CK  100  100  000    -    0
 +
197 Current_Pending_Sector  -O---K  100  100  000    -    0
 +
198 Offline_Uncorrectable  ---R--  100  100  000    -    0
 +
199 UDMA_CRC_Error_Count    -O-R--  200  200  000    -    0
 +
                            ||||||_ K auto-keep
 +
                            |||||__ C event count
 +
                            ||||___ R error rate
 +
                            |||____ S speed/performance
 +
                            ||_____ O updated online
 +
                            |______ P prefailure warning
 +
 +
General Purpose Log Directory Version 1
 +
SMART          Log Directory Version 1 [multi-sector log support]
 +
Address    Access  R/W  Size  Description
 +
0x00      GPL,SL  R/O      1  Log Directory
 +
0x01          SL  R/O      1  Summary SMART error log
 +
0x03      GPL    R/O      1  Ext. Comprehensive SMART error log
 +
0x04      GPL    R/O      7  Device Statistics log
 +
0x06          SL  R/O      1  SMART self-test log
 +
0x07      GPL    R/O      1  Extended self-test log
 +
0x08      GPL    R/O      2  Power Conditions log
 +
0x09          SL  R/W      1  Selective self-test log
 +
0x10      GPL    R/O      1  SATA NCQ Queued Error log
 +
0x11      GPL    R/O      1  SATA Phy Event Counters log
 +
0x20      GPL    R/O      1  Streaming performance log [OBS-8]
 +
0x21      GPL    R/O      1  Write stream error log
 +
0x22      GPL    R/O      1  Read stream error log
 +
0x80-0x9f  GPL,SL  R/W    16  Host vendor specific log
 +
0xe0      GPL,SL  R/W      1  SCT Command/Status
 +
0xe1      GPL,SL  R/W      1  SCT Data Transfer
 +
 +
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
 +
No Errors Logged
 +
 +
SMART Extended Self-test Log Version: 1 (1 sectors)
 +
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
 +
# 1  Extended offline    Completed without error      00%    49968        -
 +
 +
SMART Selective self-test log data structure revision number 1
 +
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
 +
    1        0        0  Not_testing
 +
    2        0        0  Not_testing
 +
    3        0        0  Not_testing
 +
    4        0        0  Not_testing
 +
    5        0        0  Not_testing
 +
Selective self-test flags (0x0):
 +
  After scanning selected spans, do NOT read-scan remainder of disk.
 +
If Selective self-test is pending on power-up, resume after 0 minute delay.
 +
 +
SCT Status Version:                  3
 +
SCT Version (vendor specific):      256 (0x0100)
 +
SCT Support Level:                  1
 +
Device State:                        SMART Off-line Data Collection executing in background (4)
 +
Current Temperature:                    27 Celsius
 +
Power Cycle Min/Max Temperature:    24/39 Celsius
 +
Lifetime    Min/Max Temperature:    17/41 Celsius
 +
Under/Over Temperature Limit Count:  0/0
 +
 +
SCT Temperature History Version:    2
 +
Temperature Sampling Period:        1 minute
 +
Temperature Logging Interval:        1 minute
 +
Min/Max recommended Temperature:      0/60 Celsius
 +
Min/Max Temperature Limit:          -40/70 Celsius
 +
Temperature History Size (Index):    128 (69)
 +
 +
Index    Estimated Time  Temperature Celsius
 +
  70    2017-10-10 09:05    27  ********
 +
 +
SCT Error Recovery Control:
 +
          Read: Disabled
 +
          Write: Disabled
 +
 +
Device Statistics (GP Log 0x04)
 +
Page Offset Size        Value  Description
 +
  1  =====  =                =  == General Statistics (rev 1) ==
 +
  1  0x008  4              14  Lifetime Power-On Resets
 +
  1  0x010  4            50018  Power-on Hours
 +
  1  0x018  6      17970047602  Logical Sectors Written
 +
  1  0x020  6        204753509  Number of Write Commands
 +
  1  0x028  6    420723716215  Logical Sectors Read
 +
  1  0x030  6      12875958968  Number of Read Commands
 +
  3  =====  =                =  == Rotating Media Statistics (rev 1) ==
 +
  3  0x008  4            50010  Spindle Motor Power-on Hours
 +
  3  0x010  4            50010  Head Flying Hours
 +
  3  0x018  4            1512  Head Load Events
 +
  3  0x020  4                0  Number of Reallocated Logical Sectors
 +
  3  0x028  4              23  Read Recovery Attempts
 +
  3  0x030  4                0  Number of Mechanical Start Failures
 +
  4  =====  =                =  == General Errors Statistics (rev 1) ==
 +
  4  0x008  4                0  Number of Reported Uncorrectable Errors
 +
  4  0x010  4                0  Resets Between Cmd Acceptance and Completion
 +
  5  =====  =                =  == Temperature Statistics (rev 1) ==
 +
  5  0x008  1              27  Current Temperature
 +
  5  0x010  1              26~ Average Short Term Temperature
 +
  5  0x018  1              26~ Average Long Term Temperature
 +
  5  0x020  1              41  Highest Temperature
 +
  5  0x028  1              17  Lowest Temperature
 +
  5  0x030  1              33~ Highest Average Short Term Temperature
 +
  5  0x038  1              25~ Lowest Average Short Term Temperature
 +
  5  0x040  1              32~ Highest Average Long Term Temperature
 +
  5  0x048  1              25~ Lowest Average Long Term Temperature
 +
  5  0x050  4                0  Time in Over-Temperature
 +
  5  0x058  1              60  Specified Maximum Operating Temperature
 +
  5  0x060  4                0  Time in Under-Temperature
 +
  5  0x068  1                0  Specified Minimum Operating Temperature
 +
  6  =====  =                =  == Transport Statistics (rev 1) ==
 +
  6  0x008  4              29  Number of Hardware Resets
 +
  6  0x010  4              21  Number of ASR Events
 
   6  0x018  4                0  Number of Interface CRC Errors
 
   6  0x018  4                0  Number of Interface CRC Errors
 
                               |_ ~ normalized value
 
                               |_ ~ normalized value
Line 210: Line 805:
 
ID      Size    Value  Description
 
ID      Size    Value  Description
 
0x0001  2            0  Command failed due to ICRC error
 
0x0001  2            0  Command failed due to ICRC error
 +
 +
</pre>
 +
 +
== Non-Raid drives ==
 +
 +
= Samsung drives =
 +
== Raid drives ==
 +
==== SAMSUNG MZ7KM480HAHP-00005 ====
 +
<pre>
 +
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
 +
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
 +
 +
=== START OF INFORMATION SECTION ===
 +
Device Model:    SAMSUNG MZ7KM480HAHP-00005
 +
Serial Number:    S2HSNX0H801784
 +
LU WWN Device Id: 5 002538 c403a4fbc
 +
Firmware Version: GXM1003Q
 +
User Capacity:    480,103,981,056 bytes [480 GB]
 +
Sector Size:      512 bytes logical/physical
 +
Rotation Rate:    Solid State Device
 +
Device is:        Not in smartctl database [for details use: -P showall]
 +
ATA Version is:  ACS-2, ATA8-ACS T13/1699-D revision 4c
 +
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
 +
Local Time is:    Tue Oct 10 10:13:39 2017 UTC
 +
SMART support is: Available - device has SMART capability.
 +
SMART support is: Enabled
 +
AAM feature is:  Unavailable
 +
APM feature is:  Unavailable
 +
Rd look-ahead is: Enabled
 +
Write cache is:  Enabled
 +
ATA Security is:  Disabled, NOT FROZEN [SEC1]
 +
Wt Cache Reorder: Enabled
 +
 +
=== START OF READ SMART DATA SECTION ===
 +
SMART overall-health self-assessment test result: PASSED
 +
 +
General SMART Values:
 +
Offline data collection status:  (0x02) Offline data collection activity
 +
was completed without error.
 +
Auto Offline Data Collection: Disabled.
 +
Self-test execution status:      (  0) The previous self-test routine completed
 +
without error or no self-test has ever
 +
been run.
 +
Total time to complete Offline
 +
data collection: ( 2100) seconds.
 +
Offline data collection
 +
capabilities: (0x53) SMART execute Offline immediate.
 +
Auto Offline data collection on/off support.
 +
Suspend Offline collection upon new
 +
command.
 +
No Offline surface scan supported.
 +
Self-test supported.
 +
No Conveyance Self-test supported.
 +
Selective Self-test supported.
 +
SMART capabilities:            (0x0003) Saves SMART data before entering
 +
power-saving mode.
 +
Supports SMART auto save timer.
 +
Error logging capability:        (0x01) Error logging supported.
 +
General Purpose Logging supported.
 +
Short self-test routine
 +
recommended polling time: (  2) minutes.
 +
Extended self-test routine
 +
recommended polling time: (  35) minutes.
 +
SCT capabilities:       (0x003d) SCT Status supported.
 +
SCT Error Recovery Control supported.
 +
SCT Feature Control supported.
 +
SCT Data Table supported.
 +
 +
SMART Attributes Data Structure revision number: 1
 +
Vendor Specific SMART Attributes with Thresholds:
 +
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
 +
  5 Reallocated_Sector_Ct  PO--CK  100  100  010    -    0
 +
  9 Power_On_Hours          -O--CK  098  098  000    -    6523
 +
12 Power_Cycle_Count      -O--CK  099  099  000    -    13
 +
177 Wear_Leveling_Count    PO--C-  099  099  005    -    7
 +
179 Used_Rsvd_Blk_Cnt_Tot  PO--C-  100  100  010    -    0
 +
180 Unused_Rsvd_Blk_Cnt_Tot PO--C-  100  100  010    -    3837
 +
181 Program_Fail_Cnt_Total  -O--CK  100  100  010    -    0
 +
182 Erase_Fail_Count_Total  -O--CK  100  100  010    -    0
 +
183 Runtime_Bad_Block      PO--C-  100  100  010    -    0
 +
184 End-to-End_Error        PO--CK  100  100  097    -    0
 +
187 Reported_Uncorrect      -O--CK  100  100  000    -    0
 +
190 Airflow_Temperature_Cel -O--CK  065  059  000    -    35
 +
195 Hardware_ECC_Recovered  -O-RC-  200  200  000    -    0
 +
197 Current_Pending_Sector  -O--CK  100  100  000    -    0
 +
199 UDMA_CRC_Error_Count    -OSRCK  100  100  000    -    0
 +
202 Unknown_SSD_Attribute  PO--CK  100  100  010    -    0
 +
235 Unknown_Attribute      -O--C-  099  099  000    -    8
 +
241 Total_LBAs_Written      -O--CK  099  099  000    -    744789435
 +
242 Total_LBAs_Read        -O--CK  099  099  000    -    141692277
 +
243 Unknown_Attribute      -O--CK  100  100  000    -    0
 +
244 Unknown_Attribute      -O--CK  100  100  000    -    0
 +
245 Unknown_Attribute      -O--CK  100  100  000    -    65535
 +
246 Unknown_Attribute      -O--CK  100  100  000    -    65535
 +
247 Unknown_Attribute      -O--CK  100  100  000    -    65535
 +
251 Unknown_Attribute      -O--CK  100  100  000    -    10942216040
 +
                            ||||||_ K auto-keep
 +
                            |||||__ C event count
 +
                            ||||___ R error rate
 +
                            |||____ S speed/performance
 +
                            ||_____ O updated online
 +
                            |______ P prefailure warning
 +
 +
General Purpose Log Directory Version 1
 +
SMART          Log Directory Version 1 [multi-sector log support]
 +
Address    Access  R/W  Size  Description
 +
0x00      GPL,SL  R/O      1  Log Directory
 +
0x01          SL  R/O      1  Summary SMART error log
 +
0x02          SL  R/O      1  Comprehensive SMART error log
 +
0x03      GPL    R/O      1  Ext. Comprehensive SMART error log
 +
0x06          SL  R/O      1  SMART self-test log
 +
0x07      GPL    R/O      1  Extended self-test log
 +
0x09          SL  R/W      1  Selective self-test log
 +
0x10      GPL    R/O      1  SATA NCQ Queued Error log
 +
0x11      GPL    R/O      1  SATA Phy Event Counters log
 +
0x13      GPL    R/O      1  SATA NCQ Send and Receive log
 +
0x30      GPL,SL  R/O      9  IDENTIFY DEVICE data log
 +
0x80-0x9f  GPL,SL  R/W    16  Host vendor specific log
 +
0xce          SL  VS      16  Device vendor specific log
 +
0xe0      GPL,SL  R/W      1  SCT Command/Status
 +
0xe1      GPL,SL  R/W      1  SCT Data Transfer
 +
 +
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
 +
No Errors Logged
 +
 +
SMART Extended Self-test Log Version: 1 (1 sectors)
 +
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
 +
# 1  Extended offline    Completed without error      00%      6466        -
 +
 +
SMART Selective self-test log data structure revision number 1
 +
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
 +
    1        0        0  Not_testing
 +
    2        0        0  Not_testing
 +
    3        0        0  Not_testing
 +
    4        0        0  Not_testing
 +
    5        0        0  Not_testing
 +
  255        0    65535  Read_scanning was completed without error
 +
Selective self-test flags (0x0):
 +
  After scanning selected spans, do NOT read-scan remainder of disk.
 +
If Selective self-test is pending on power-up, resume after 0 minute delay.
 +
 +
SCT Status Version:                  3
 +
SCT Version (vendor specific):      256 (0x0100)
 +
SCT Support Level:                  1
 +
Device State:                        SCT command executing in background (5)
 +
Current Temperature:                    35 Celsius
 +
Power Cycle Min/Max Temperature:    32/38 Celsius
 +
Lifetime    Min/Max Temperature:      0/70 Celsius
 +
Under/Over Temperature Limit Count:  4294967295/4294967295
 +
 +
SCT Temperature History Version:    3 (Unknown, should be 2)
 +
Temperature Sampling Period:        1 minute
 +
Temperature Logging Interval:        10 minutes
 +
Min/Max recommended Temperature:      0/70 Celsius
 +
Min/Max Temperature Limit:            0/70 Celsius
 +
Temperature History Size (Index):    128 (88)
 +
 +
Index    Estimated Time  Temperature Celsius
 +
  89    2017-10-09 13:00    34  ***************
 +
 +
SCT Error Recovery Control:
 +
          Read: Disabled
 +
          Write: Disabled
 +
 +
Device Statistics (GP/SMART Log 0x04) not supported
 +
 +
SATA Phy Event Counters (GP Log 0x11)
 +
ID      Size    Value  Description
 +
0x0001  2            0  Command failed due to ICRC error
 +
0x0002  2            0  R_ERR response for data FIS
 +
0x0003  2            0  R_ERR response for device-to-host data FIS
 +
0x0004  2            0  R_ERR response for host-to-device data FIS
 +
0x0005  2            0  R_ERR response for non-data FIS
 +
0x0006  2            0  R_ERR response for device-to-host non-data FIS
 +
0x0007  2            0  R_ERR response for host-to-device non-data FIS
 +
0x0008  2            0  Device-to-host non-data FIS retries
 +
0x0009  2          19  Transition from drive PhyRdy to drive PhyNRdy
 +
0x000a  2          19  Device-to-host register FISes sent due to a COMRESET
 +
0x000b  2            0  CRC errors within host-to-device FIS
 +
0x000d  2            0  Non-CRC errors within host-to-device FIS
 +
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
 +
0x0010  2            0  R_ERR response for host-to-device data FIS, non-CRC
 +
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
 +
0x0013  2            0  R_ERR response for host-to-device non-data FIS, non-CRC
 +
 +
</pre>
 +
 +
==== SAMSUNG MZ7LN128HCHP-00000 ====
 +
<pre>
 +
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
 +
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
 +
 +
=== START OF INFORMATION SECTION ===
 +
Device Model:    SAMSUNG MZ7LN128HCHP-00000
 +
Serial Number:    S1ZFNXAG652991
 +
LU WWN Device Id: 5 002538 d40286c3d
 +
Firmware Version: EMT0100Q
 +
User Capacity:    128,035,676,160 bytes [128 GB]
 +
Sector Size:      512 bytes logical/physical
 +
Rotation Rate:    Solid State Device
 +
Device is:        Not in smartctl database [for details use: -P showall]
 +
ATA Version is:  ACS-2, ATA8-ACS T13/1699-D revision 4c
 +
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
 +
Local Time is:    Tue Oct 10 12:14:03 2017 CEST
 +
SMART support is: Available - device has SMART capability.
 +
SMART support is: Enabled
 +
AAM feature is:  Unavailable
 +
APM feature is:  Unavailable
 +
Rd look-ahead is: Enabled
 +
Write cache is:  Enabled
 +
ATA Security is:  Disabled, NOT FROZEN [SEC1]
 +
Wt Cache Reorder: Enabled
 +
 +
=== START OF READ SMART DATA SECTION ===
 +
SMART overall-health self-assessment test result: PASSED
 +
 +
General SMART Values:
 +
Offline data collection status:  (0x00) Offline data collection activity
 +
was never started.
 +
Auto Offline Data Collection: Disabled.
 +
Self-test execution status:      (  0) The previous self-test routine completed
 +
without error or no self-test has ever
 +
been run.
 +
Total time to complete Offline
 +
data collection: (    0) seconds.
 +
Offline data collection
 +
capabilities: (0x53) SMART execute Offline immediate.
 +
Auto Offline data collection on/off support.
 +
Suspend Offline collection upon new
 +
command.
 +
No Offline surface scan supported.
 +
Self-test supported.
 +
No Conveyance Self-test supported.
 +
Selective Self-test supported.
 +
SMART capabilities:            (0x0003) Saves SMART data before entering
 +
power-saving mode.
 +
Supports SMART auto save timer.
 +
Error logging capability:        (0x01) Error logging supported.
 +
General Purpose Logging supported.
 +
Short self-test routine
 +
recommended polling time: (  2) minutes.
 +
Extended self-test routine
 +
recommended polling time: (  64) minutes.
 +
SCT capabilities:       (0x003d) SCT Status supported.
 +
SCT Error Recovery Control supported.
 +
SCT Feature Control supported.
 +
SCT Data Table supported.
 +
 +
SMART Attributes Data Structure revision number: 1
 +
Vendor Specific SMART Attributes with Thresholds:
 +
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
 +
  5 Reallocated_Sector_Ct  PO--CK  100  100  010    -    0
 +
  9 Power_On_Hours          -O--CK  096  096  000    -    16093
 +
12 Power_Cycle_Count      -O--CK  099  099  000    -    7
 +
170 Unknown_Attribute      -O--CK  100  100  010    -    0
 +
171 Unknown_Attribute      -O--CK  100  100  010    -    0
 +
172 Unknown_Attribute      -O--CK  100  100  010    -    0
 +
173 Unknown_Attribute      PO--CK  097  097  005    -    52
 +
174 Unknown_Attribute      -O--CK  099  099  000    -    3
 +
178 Used_Rsvd_Blk_Cnt_Chip  PO--C-  100  100  010    -    0
 +
180 Unused_Rsvd_Blk_Cnt_Tot PO--C-  100  100  010    -    325
 +
184 End-to-End_Error        PO--CK  100  100  097    -    0
 +
187 Reported_Uncorrect      -O--CK  100  100  000    -    0
 +
194 Temperature_Celsius    -O--CK  068  055  000    -    32
 +
199 UDMA_CRC_Error_Count    -OSRCK  100  100  000    -    0
 +
233 Media_Wearout_Indicator PO--C-  097  097  000    -    16341007
 +
241 Total_LBAs_Written      -O--CK  099  099  000    -    2219
 +
242 Total_LBAs_Read        -O--CK  099  099  000    -    5
 +
249 Unknown_Attribute      -O--CK  099  099  000    -    6688
 +
                            ||||||_ K auto-keep
 +
                            |||||__ C event count
 +
                            ||||___ R error rate
 +
                            |||____ S speed/performance
 +
                            ||_____ O updated online
 +
                            |______ P prefailure warning
 +
 +
General Purpose Log Directory Version 1
 +
SMART          Log Directory Version 1 [multi-sector log support]
 +
Address    Access  R/W  Size  Description
 +
0x00      GPL,SL  R/O      1  Log Directory
 +
0x01          SL  R/O      1  Summary SMART error log
 +
0x02          SL  R/O      1  Comprehensive SMART error log
 +
0x03      GPL    R/O      1  Ext. Comprehensive SMART error log
 +
0x06          SL  R/O      1  SMART self-test log
 +
0x07      GPL    R/O      1  Extended self-test log
 +
0x09          SL  R/W      1  Selective self-test log
 +
0x10      GPL    R/O      1  SATA NCQ Queued Error log
 +
0x11      GPL    R/O      1  SATA Phy Event Counters log
 +
0x13      GPL    R/O      1  SATA NCQ Send and Receive log
 +
0x30      GPL,SL  R/O      9  IDENTIFY DEVICE data log
 +
0x80-0x9f  GPL,SL  R/W    16  Host vendor specific log
 +
0xdf      GPL,SL  VS      1  Device vendor specific log
 +
0xe0      GPL,SL  R/W      1  SCT Command/Status
 +
0xe1      GPL,SL  R/W      1  SCT Data Transfer
 +
 +
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
 +
No Errors Logged
 +
 +
SMART Extended Self-test Log Version: 1 (1 sectors)
 +
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
 +
# 1  Extended offline    Completed without error      00%    15950        -
 +
 +
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
 +
SMART Selective self-test log data structure revision number 1
 +
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
 +
    1        0        0  Not_testing
 +
    2        0        0  Not_testing
 +
    3        0        0  Not_testing
 +
    4        0        0  Not_testing
 +
    5        0        0  Not_testing
 +
  255        0    65535  Read_scanning was never started
 +
Selective self-test flags (0x0):
 +
  After scanning selected spans, do NOT read-scan remainder of disk.
 +
If Selective self-test is pending on power-up, resume after 0 minute delay.
 +
 +
SCT Status Version:                  3
 +
SCT Version (vendor specific):      256 (0x0100)
 +
SCT Support Level:                  1
 +
Device State:                        SCT command executing in background (5)
 +
Current Temperature:                    32 Celsius
 +
Power Cycle Min/Max Temperature:    30/45 Celsius
 +
Lifetime    Min/Max Temperature:      0/70 Celsius
 +
Under/Over Temperature Limit Count:  1048576/0
 +
 +
SCT Temperature History Version:    3 (Unknown, should be 2)
 +
Temperature Sampling Period:        1 minute
 +
Temperature Logging Interval:        10 minutes
 +
Min/Max recommended Temperature:      0/70 Celsius
 +
Min/Max Temperature Limit:            0/70 Celsius
 +
Temperature History Size (Index):    128 (77)
 +
 +
Index    Estimated Time  Temperature Celsius
 +
  77    2017-10-10 12:10    32  *************
 +
 +
SCT Error Recovery Control:
 +
          Read: Disabled
 +
          Write: Disabled
 +
 +
Device Statistics (GP/SMART Log 0x04) not supported
 +
 +
SATA Phy Event Counters (GP Log 0x11)
 +
ID      Size    Value  Description
 +
0x0001  2            0  Command failed due to ICRC error
 +
0x0002  2            0  R_ERR response for data FIS
 +
0x0003  2            0  R_ERR response for device-to-host data FIS
 +
0x0004  2            0  R_ERR response for host-to-device data FIS
 +
0x0005  2            0  R_ERR response for non-data FIS
 +
0x0006  2            0  R_ERR response for device-to-host non-data FIS
 +
0x0007  2            0  R_ERR response for host-to-device non-data FIS
 +
0x0008  2            0  Device-to-host non-data FIS retries
 +
0x0009  2          19  Transition from drive PhyRdy to drive PhyNRdy
 +
0x000a  2          19  Device-to-host register FISes sent due to a COMRESET
 +
0x000b  2            0  CRC errors within host-to-device FIS
 +
0x000d  2            0  Non-CRC errors within host-to-device FIS
 +
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
 +
0x0010  2            0  R_ERR response for host-to-device data FIS, non-CRC
 +
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
 +
0x0013  2            0  R_ERR response for host-to-device non-data FIS, non-CRC
  
 
</pre>
 
</pre>
Line 221: Line 1,174:
 
Seagate Ironwolf
 
Seagate Ironwolf
  
=== Seagate Samsung Spinpoint ===
+
=== Seagate Constellation ===
 +
==== ST2000NM0033-9ZM175 (2TB) ====
 +
<pre>
 +
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-2.6.32-openvz-042stab123.8-amd64] (local build)
 +
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  
 +
=== START OF INFORMATION SECTION ===
 +
Device Model:    ST2000NM0033-9ZM175
 +
Serial Number:    Z1Y0MAX4
 +
LU WWN Device Id: 5 000c50 064b09f28
 +
Firmware Version: SN03
 +
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
 +
Sector Size:      512 bytes logical/physical
 +
Device is:        Not in smartctl database [for details use: -P showall]
 +
ATA Version is:  9
 +
ATA Standard is:  Exact ATA specification draft version not indicated
 +
Local Time is:    Tue Oct 10 10:29:06 2017 UTC
 +
SMART support is: Available - device has SMART capability.
 +
SMART support is: Enabled
 +
 +
=== START OF READ SMART DATA SECTION ===
 +
SMART overall-health self-assessment test result: PASSED
 +
 +
General SMART Values:
 +
Offline data collection status:  (0x82) Offline data collection activity
 +
was completed without error.
 +
Auto Offline Data Collection: Enabled.
 +
Self-test execution status:      (  0) The previous self-test routine completed
 +
without error or no self-test has ever
 +
been run.
 +
Total time to complete Offline
 +
data collection: (  592) seconds.
 +
Offline data collection
 +
capabilities: (0x7b) SMART execute Offline immediate.
 +
Auto Offline data collection on/off support.
 +
Suspend Offline collection upon new
 +
command.
 +
Offline surface scan supported.
 +
Self-test supported.
 +
Conveyance Self-test supported.
 +
Selective Self-test supported.
 +
SMART capabilities:            (0x0003) Saves SMART data before entering
 +
power-saving mode.
 +
Supports SMART auto save timer.
 +
Error logging capability:        (0x01) Error logging supported.
 +
General Purpose Logging supported.
 +
Short self-test routine
 +
recommended polling time: (  1) minutes.
 +
Extended self-test routine
 +
recommended polling time: ( 246) minutes.
 +
Conveyance self-test routine
 +
recommended polling time: (  2) minutes.
 +
SCT capabilities:       (0x50bd) SCT Status supported.
 +
SCT Error Recovery Control supported.
 +
SCT Feature Control supported.
 +
SCT Data Table supported.
 +
 +
SMART Attributes Data Structure revision number: 10
 +
Vendor Specific SMART Attributes with Thresholds:
 +
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
 +
  1 Raw_Read_Error_Rate    POSR--  084  063  044    -    2318897
 +
  3 Spin_Up_Time            PO----  094  094  000    -    0
 +
  4 Start_Stop_Count        -O--CK  100  100  020    -    9
 +
  5 Reallocated_Sector_Ct  PO--CK  100  100  010    -    0
 +
  7 Seek_Error_Rate        POSR--  095  060  030    -    3348031798
 +
  9 Power_On_Hours          -O--CK  061  061  000    -    34301
 +
10 Spin_Retry_Count        PO--C-  100  100  097    -    0
 +
12 Power_Cycle_Count      -O--CK  100  100  020    -    9
 +
184 End-to-End_Error        -O--CK  100  100  099    -    0
 +
187 Reported_Uncorrect      -O--CK  100  100  000    -    0
 +
188 Command_Timeout        -O--CK  100  100  000    -    0
 +
189 High_Fly_Writes        -O-RCK  100  100  000    -    0
 +
190 Airflow_Temperature_Cel -O---K  068  061  045    -    32 (Min/Max 23/39)
 +
191 G-Sense_Error_Rate      -O--CK  100  100  000    -    0
 +
192 Power-Off_Retract_Count -O--CK  100  100  000    -    6
 +
193 Load_Cycle_Count        -O--CK  100  100  000    -    1458
 +
194 Temperature_Celsius    -O---K  032  040  000    -    32 (0 22 0 0)
 +
195 Hardware_ECC_Recovered  -O-RC-  043  009  000    -    2318897
 +
197 Current_Pending_Sector  -O--C-  100  100  000    -    0
 +
198 Offline_Uncorrectable  ----C-  100  100  000    -    0
 +
199 UDMA_CRC_Error_Count    -OSRCK  200  200  000    -    0
 +
                            ||||||_ K auto-keep
 +
                            |||||__ C event count
 +
                            ||||___ R error rate
 +
                            |||____ S speed/performance
 +
                            ||_____ O updated online
 +
                            |______ P prefailure warning
 +
 +
General Purpose Log Directory Version 1
 +
SMART          Log Directory Version 1 [multi-sector log support]
 +
GP/S  Log at address 0x00 has    1 sectors [Log Directory]
 +
SMART Log at address 0x01 has    1 sectors [Summary SMART error log]
 +
SMART Log at address 0x02 has    5 sectors [Comprehensive SMART error log]
 +
GP    Log at address 0x03 has    5 sectors [Ext. Comprehensive SMART error log]
 +
SMART Log at address 0x06 has    1 sectors [SMART self-test log]
 +
GP    Log at address 0x07 has    1 sectors [Extended self-test log]
 +
GP/S  Log at address 0x08 has    2 sectors [Power Conditions]
 +
SMART Log at address 0x09 has    1 sectors [Selective self-test log]
 +
GP    Log at address 0x10 has    1 sectors [NCQ Command Error]
 +
GP    Log at address 0x11 has    1 sectors [SATA Phy Event Counters]
 +
GP    Log at address 0x21 has    1 sectors [Write stream error log]
 +
GP    Log at address 0x22 has    1 sectors [Read stream error log]
 +
GP/S  Log at address 0x30 has    9 sectors [Reserved]
 +
GP/S  Log at address 0x80 has  16 sectors [Host vendor specific log]
 +
GP/S  Log at address 0xe0 has    1 sectors [SCT Command/Status]
 +
GP/S  Log at address 0xe1 has    1 sectors [SCT Data Transfer]
 +
 +
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
 +
No Errors Logged
 +
 +
SMART Extended Self-test Log Version: 1 (1 sectors)
 +
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
 +
# 1  Extended offline    Completed without error      00%    25207        -
 +
# 2  Extended offline    Completed without error      00%    12345        -
 +
# 3  Extended offline    Completed without error      00%      879        -
 +
# 4  Extended offline    Completed without error      00%        3        -
 +
 +
SMART Selective self-test log data structure revision number 1
 +
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
 +
    1        0        0  Not_testing
 +
    2        0        0  Not_testing
 +
    3        0        0  Not_testing
 +
    4        0        0  Not_testing
 +
    5        0        0  Not_testing
 +
Selective self-test flags (0x0):
 +
  After scanning selected spans, do NOT read-scan remainder of disk.
 +
If Selective self-test is pending on power-up, resume after 0 minute delay.
 +
 +
SCT Status Version:                  3
 +
SCT Version (vendor specific):      522 (0x020a)
 +
SCT Support Level:                  1
 +
Device State:                        Active (0)
 +
Current Temperature:                    32 Celsius
 +
Power Cycle Min/Max Temperature:    23/39 Celsius
 +
Lifetime    Min/Max Temperature:    22/39 Celsius
 +
Under/Over Temperature Limit Count:  0/205519
 +
SCT Temperature History Version:    2
 +
Temperature Sampling Period:        1 minute
 +
Temperature Logging Interval:        10 minutes
 +
Min/Max recommended Temperature:      0/ 0 Celsius
 +
Min/Max Temperature Limit:            0/ 0 Celsius
 +
Temperature History Size (Index):    128 (18)
 +
 +
Index    Estimated Time  Temperature Celsius
 +
  19    2017-10-09 13:10    32  *************
 +
...    ..(126 skipped).    ..  *************
 +
  18    2017-10-10 10:20    32  *************
 +
 +
SCT Error Recovery Control:
 +
          Read:    100 (10.0 seconds)
 +
          Write:    100 (10.0 seconds)
 +
 +
SATA Phy Event Counters (GP Log 0x11)
 +
ID      Size    Value  Description
 +
0x000a  2          115  Device-to-host register FISes sent due to a COMRESET
 +
0x0001  2            0  Command failed due to ICRC error
 +
0x0003  2            0  R_ERR response for device-to-host data FIS
 +
0x0004  2            0  R_ERR response for host-to-device data FIS
 +
0x0006  2            0  R_ERR response for device-to-host non-data FIS
 +
0x0007  2            0  R_ERR response for host-to-device non-data FIS
 +
 +
</pre>
 +
==== ST91000640NS (1TB) ====
 +
<pre>
 +
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.16.0-0.bpo.4-amd64] (local build)
 +
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
 +
 +
=== START OF INFORMATION SECTION ===
 +
Device Model:    ST91000640NS
 +
Serial Number:    9XG4ZBZJ
 +
LU WWN Device Id: 5 000c50 064438461
 +
Firmware Version: SN03
 +
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
 +
Sector Size:      512 bytes logical/physical
 +
Device is:        Not in smartctl database [for details use: -P showall]
 +
ATA Version is:  8
 +
ATA Standard is:  ATA-8-ACS revision 4
 +
Local Time is:    Tue Oct 10 12:16:17 2017 CEST
 +
SMART support is: Available - device has SMART capability.
 +
SMART support is: Enabled
 +
 +
=== START OF READ SMART DATA SECTION ===
 +
SMART overall-health self-assessment test result: PASSED
 +
 +
General SMART Values:
 +
Offline data collection status:  (0x82) Offline data collection activity
 +
was completed without error.
 +
Auto Offline Data Collection: Enabled.
 +
Self-test execution status:      (  0) The previous self-test routine completed
 +
without error or no self-test has ever
 +
been run.
 +
Total time to complete Offline
 +
data collection: (  642) seconds.
 +
Offline data collection
 +
capabilities: (0x7b) SMART execute Offline immediate.
 +
Auto Offline data collection on/off support.
 +
Suspend Offline collection upon new
 +
command.
 +
Offline surface scan supported.
 +
Self-test supported.
 +
Conveyance Self-test supported.
 +
Selective Self-test supported.
 +
SMART capabilities:            (0x0003) Saves SMART data before entering
 +
power-saving mode.
 +
Supports SMART auto save timer.
 +
Error logging capability:        (0x01) Error logging supported.
 +
General Purpose Logging supported.
 +
Short self-test routine
 +
recommended polling time: (  1) minutes.
 +
Extended self-test routine
 +
recommended polling time: ( 203) minutes.
 +
Conveyance self-test routine
 +
recommended polling time: (  2) minutes.
 +
SCT capabilities:       (0x10bd) SCT Status supported.
 +
SCT Error Recovery Control supported.
 +
SCT Feature Control supported.
 +
SCT Data Table supported.
 +
 +
SMART Attributes Data Structure revision number: 10
 +
Vendor Specific SMART Attributes with Thresholds:
 +
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
 +
  1 Raw_Read_Error_Rate    POSR--  079  064  044    -    91112581
 +
  3 Spin_Up_Time            PO----  094  094  000    -    0
 +
  4 Start_Stop_Count        -O--CK  100  100  020    -    11
 +
  5 Reallocated_Sector_Ct  PO--CK  100  100  036    -    0
 +
  7 Seek_Error_Rate        POSR--  078  060  030    -    67076501
 +
  9 Power_On_Hours          -O--CK  074  074  000    -    23393
 +
10 Spin_Retry_Count        PO--C-  100  100  097    -    0
 +
12 Power_Cycle_Count      -O--CK  100  100  020    -    11
 +
184 End-to-End_Error        -O--CK  100  100  099    -    0
 +
187 Reported_Uncorrect      -O--CK  100  100  000    -    0
 +
188 Command_Timeout        -O--CK  100  100  000    -    0
 +
189 High_Fly_Writes        -O-RCK  100  100  000    -    0
 +
190 Airflow_Temperature_Cel -O---K  063  053  045    -    37 (Min/Max 29/47)
 +
191 G-Sense_Error_Rate      -O--CK  100  100  000    -    0
 +
192 Power-Off_Retract_Count -O--CK  100  100  000    -    7
 +
193 Load_Cycle_Count        -O--CK  100  100  000    -    13
 +
194 Temperature_Celsius    -O---K  037  047  000    -    37 (0 19 0 0)
 +
195 Hardware_ECC_Recovered  -O-RC-  115  100  000    -    91112581
 +
197 Current_Pending_Sector  -O--C-  100  100  000    -    0
 +
198 Offline_Uncorrectable  ----C-  100  100  000    -    0
 +
199 UDMA_CRC_Error_Count    -OSRCK  200  200  000    -    0
 +
                            ||||||_ K auto-keep
 +
                            |||||__ C event count
 +
                            ||||___ R error rate
 +
                            |||____ S speed/performance
 +
                            ||_____ O updated online
 +
                            |______ P prefailure warning
 +
 +
General Purpose Log Directory Version 1
 +
SMART          Log Directory Version 1 [multi-sector log support]
 +
GP/S  Log at address 0x00 has    1 sectors [Log Directory]
 +
SMART Log at address 0x01 has    1 sectors [Summary SMART error log]
 +
SMART Log at address 0x02 has    5 sectors [Comprehensive SMART error log]
 +
GP    Log at address 0x03 has    5 sectors [Ext. Comprehensive SMART error log]
 +
SMART Log at address 0x06 has    1 sectors [SMART self-test log]
 +
GP    Log at address 0x07 has    1 sectors [Extended self-test log]
 +
SMART Log at address 0x09 has    1 sectors [Selective self-test log]
 +
GP    Log at address 0x10 has    1 sectors [NCQ Command Error]
 +
GP    Log at address 0x11 has    1 sectors [SATA Phy Event Counters]
 +
GP/S  Log at address 0x12 has    1 sectors [Reserved for Serial ATA]
 +
GP    Log at address 0x21 has    1 sectors [Write stream error log]
 +
GP    Log at address 0x22 has    1 sectors [Read stream error log]
 +
GP/S  Log at address 0x80 has  16 sectors [Host vendor specific log]
 +
GP    Log at address 0xbf has 65535 sectors [Device vendor specific log]
 +
GP/S  Log at address 0xe0 has    1 sectors [SCT Command/Status]
 +
GP/S  Log at address 0xe1 has    1 sectors [SCT Data Transfer]
 +
 +
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
 +
No Errors Logged
 +
 +
SMART Extended Self-test Log Version: 1 (1 sectors)
 +
No self-tests have been logged.  [To run self-tests, use: smartctl -t]
 +
 +
SMART Selective self-test log data structure revision number 1
 +
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
 +
    1        0        0  Not_testing
 +
    2        0        0  Not_testing
 +
    3        0        0  Not_testing
 +
    4        0        0  Not_testing
 +
    5        0        0  Not_testing
 +
Selective self-test flags (0x0):
 +
  After scanning selected spans, do NOT read-scan remainder of disk.
 +
If Selective self-test is pending on power-up, resume after 0 minute delay.
 +
 +
SCT Status Version:                  3
 +
SCT Version (vendor specific):      522 (0x020a)
 +
SCT Support Level:                  1
 +
Device State:                        Active (0)
 +
Current Temperature:                    37 Celsius
 +
Power Cycle Min/Max Temperature:    29/47 Celsius
 +
Lifetime    Min/Max Temperature:    19/54 Celsius
 +
Under/Over Temperature Limit Count:  0/138619
 +
SCT Temperature History Version:    2
 +
Temperature Sampling Period:        1 minute
 +
Temperature Logging Interval:        10 minutes
 +
Min/Max recommended Temperature:      0/ 0 Celsius
 +
Min/Max Temperature Limit:            0/ 0 Celsius
 +
Temperature History Size (Index):    128 (106)
 +
 +
Index    Estimated Time  Temperature Celsius
 +
106    2017-10-10 12:10    37  ******************
 +
 +
SCT Error Recovery Control:
 +
          Read:    100 (10.0 seconds)
 +
          Write:    100 (10.0 seconds)
 +
 +
SATA Phy Event Counters (GP Log 0x11)
 +
ID      Size    Value  Description
 +
0x000a  2          103  Device-to-host register FISes sent due to a COMRESET
 +
0x0001  2            0  Command failed due to ICRC error
 +
0x0003  2            0  R_ERR response for device-to-host data FIS
 +
0x0004  2            0  R_ERR response for host-to-device data FIS
 +
0x0006  2            0  R_ERR response for device-to-host non-data FIS
 +
0x0007  2            0  R_ERR response for host-to-device non-data FIS
 +
</pre>
 +
 +
=== Seagate Samsung Spinpoint ===
 
==== ST2000LM003 (2016) 2 TB ====
 
==== ST2000LM003 (2016) 2 TB ====
 
<pre>
 
<pre>
Line 742: Line 2,011:
  
 
=== WD RE4 (Gold?) ===
 
=== WD RE4 (Gold?) ===
 +
==== WDC WD1003FBYX-01Y7B1 (1TB) ====
 +
<pre>
 +
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
 +
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
 +
 +
=== START OF INFORMATION SECTION ===
 +
Model Family:    Western Digital RE4
 +
Device Model:    WDC WD1003FBYX-01Y7B1
 +
Serial Number:    WD-WCAW36571293
 +
LU WWN Device Id: 5 0014ee 25e700225
 +
Firmware Version: 01.01V02
 +
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
 +
Sector Size:      512 bytes logical/physical
 +
Rotation Rate:    7200 rpm
 +
Device is:        In smartctl database [for details use: -P show]
 +
ATA Version is:  ATA8-ACS (minor revision not indicated)
 +
SATA Version is:  SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
 +
Local Time is:    Tue Oct 10 10:13:52 2017 UTC
 +
SMART support is: Available - device has SMART capability.
 +
SMART support is: Enabled
 +
AAM feature is:  Unavailable
 +
APM level is:    254 (maximum performance)
 +
Rd look-ahead is: Enabled
 +
Write cache is:  Enabled
 +
ATA Security is:  Disabled, frozen [SEC2]
 +
Wt Cache Reorder: Enabled
 +
 +
=== START OF READ SMART DATA SECTION ===
 +
SMART overall-health self-assessment test result: PASSED
 +
 +
General SMART Values:
 +
Offline data collection status:  (0x84) Offline data collection activity
 +
was suspended by an interrupting command from host.
 +
Auto Offline Data Collection: Enabled.
 +
Self-test execution status:      (  0) The previous self-test routine completed
 +
without error or no self-test has ever
 +
been run.
 +
Total time to complete Offline
 +
data collection: (16860) seconds.
 +
Offline data collection
 +
capabilities: (0x7b) SMART execute Offline immediate.
 +
Auto Offline data collection on/off support.
 +
Suspend Offline collection upon new
 +
command.
 +
Offline surface scan supported.
 +
Self-test supported.
 +
Conveyance Self-test supported.
 +
Selective Self-test supported.
 +
SMART capabilities:            (0x0003) Saves SMART data before entering
 +
power-saving mode.
 +
Supports SMART auto save timer.
 +
Error logging capability:        (0x01) Error logging supported.
 +
General Purpose Logging supported.
 +
Short self-test routine
 +
recommended polling time: (  2) minutes.
 +
Extended self-test routine
 +
recommended polling time: ( 166) minutes.
 +
Conveyance self-test routine
 +
recommended polling time: (  5) minutes.
 +
SCT capabilities:       (0x303f) SCT Status supported.
 +
SCT Error Recovery Control supported.
 +
SCT Feature Control supported.
 +
SCT Data Table supported.
 +
 +
SMART Attributes Data Structure revision number: 16
 +
Vendor Specific SMART Attributes with Thresholds:
 +
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
 +
  1 Raw_Read_Error_Rate    POSR-K  200  200  051    -    0
 +
  3 Spin_Up_Time            POS--K  174  170  021    -    4283
 +
  4 Start_Stop_Count        -O--CK  100  100  000    -    37
 +
  5 Reallocated_Sector_Ct  PO--CK  200  200  140    -    0
 +
  7 Seek_Error_Rate        -OSR-K  200  200  000    -    0
 +
  9 Power_On_Hours          -O--CK  065  065  000    -    25633
 +
10 Spin_Retry_Count        -O--CK  100  253  000    -    0
 +
11 Calibration_Retry_Count -O--CK  100  253  000    -    0
 +
12 Power_Cycle_Count      -O--CK  100  100  000    -    36
 +
192 Power-Off_Retract_Count -O--CK  200  200  000    -    30
 +
193 Load_Cycle_Count        -O--CK  200  200  000    -    6
 +
194 Temperature_Celsius    -O---K  119  109  000    -    28
 +
196 Reallocated_Event_Count -O--CK  200  200  000    -    0
 +
197 Current_Pending_Sector  -O--CK  200  200  000    -    0
 +
198 Offline_Uncorrectable  ----CK  200  200  000    -    0
 +
199 UDMA_CRC_Error_Count    -O--CK  200  200  000    -    0
 +
200 Multi_Zone_Error_Rate  ---R--  200  200  000    -    0
 +
                            ||||||_ K auto-keep
 +
                            |||||__ C event count
 +
                            ||||___ R error rate
 +
                            |||____ S speed/performance
 +
                            ||_____ O updated online
 +
                            |______ P prefailure warning
 +
 +
General Purpose Log Directory Version 1
 +
SMART          Log Directory Version 1 [multi-sector log support]
 +
Address    Access  R/W  Size  Description
 +
0x00      GPL,SL  R/O      1  Log Directory
 +
0x01          SL  R/O      1  Summary SMART error log
 +
0x02          SL  R/O      5  Comprehensive SMART error log
 +
0x03      GPL    R/O      6  Ext. Comprehensive SMART error log
 +
0x06          SL  R/O      1  SMART self-test log
 +
0x07      GPL    R/O      1  Extended self-test log
 +
0x08      GPL    R/O      2  Power Conditions log
 +
0x09          SL  R/W      1  Selective self-test log
 +
0x10      GPL    R/O      1  SATA NCQ Queued Error log
 +
0x11      GPL    R/O      1  SATA Phy Event Counters log
 +
0x80-0x9f  GPL,SL  R/W    16  Host vendor specific log
 +
0xa0-0xa7  GPL,SL  VS      16  Device vendor specific log
 +
0xa8-0xb5  GPL,SL  VS      1  Device vendor specific log
 +
0xb6      GPL    VS      1  Device vendor specific log
 +
0xb7      GPL,SL  VS      1  Device vendor specific log
 +
0xbd      GPL,SL  VS      1  Device vendor specific log
 +
0xc0      GPL,SL  VS      1  Device vendor specific log
 +
0xc1      GPL    VS      24  Device vendor specific log
 +
0xe0      GPL,SL  R/W      1  SCT Command/Status
 +
0xe1      GPL,SL  R/W      1  SCT Data Transfer
 +
 +
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
 +
No Errors Logged
 +
 +
SMART Extended Self-test Log Version: 1 (1 sectors)
 +
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
 +
# 1  Extended offline    Completed without error      00%    25579        -
 +
 +
SMART Selective self-test log data structure revision number 1
 +
SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
 +
    1        0        0  Not_testing
 +
    2        0        0  Not_testing
 +
    3        0        0  Not_testing
 +
    4        0        0  Not_testing
 +
    5        0        0  Not_testing
 +
Selective self-test flags (0x0):
 +
  After scanning selected spans, do NOT read-scan remainder of disk.
 +
If Selective self-test is pending on power-up, resume after 0 minute delay.
 +
 +
SCT Status Version:                  3
 +
SCT Version (vendor specific):      258 (0x0102)
 +
SCT Support Level:                  1
 +
Device State:                        Active (0)
 +
Current Temperature:                    28 Celsius
 +
Power Cycle Min/Max Temperature:    27/30 Celsius
 +
Lifetime    Min/Max Temperature:    27/38 Celsius
 +
Under/Over Temperature Limit Count:  0/0
 +
 +
SCT Temperature History Version:    2
 +
Temperature Sampling Period:        1 minute
 +
Temperature Logging Interval:        1 minute
 +
Min/Max recommended Temperature:      0/60 Celsius
 +
Min/Max Temperature Limit:          -41/85 Celsius
 +
Temperature History Size (Index):    478 (137)
 +
 +
Index    Estimated Time  Temperature Celsius
 +
108    2017-10-10 09:44    27  ********
 +
109    2017-10-10 09:45    28  *********
 +
...    ..( 27 skipped).    ..  *********
 +
137    2017-10-10 10:13    28  *********
 +
 +
SCT Error Recovery Control:
 +
          Read:    70 (7.0 seconds)
 +
          Write:    70 (7.0 seconds)
 +
 +
Device Statistics (GP/SMART Log 0x04) not supported
 +
 +
SATA Phy Event Counters (GP Log 0x11)
 +
ID      Size    Value  Description
 +
0x0001  2            0  Command failed due to ICRC error
 +
0x0002  2            0  R_ERR response for data FIS
 +
0x0003  2            0  R_ERR response for device-to-host data FIS
 +
0x0004  2            0  R_ERR response for host-to-device data FIS
 +
0x0005  2            0  R_ERR response for non-data FIS
 +
0x0006  2            0  R_ERR response for device-to-host non-data FIS
 +
0x0007  2            0  R_ERR response for host-to-device non-data FIS
 +
0x0008  2            0  Device-to-host non-data FIS retries
 +
0x0009  2          11  Transition from drive PhyRdy to drive PhyNRdy
 +
0x000a  2            3  Device-to-host register FISes sent due to a COMRESET
 +
0x000b  2            0  CRC errors within host-to-device FIS
 +
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
 +
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
 +
0x8000  4      2152921  Vendor specific
 +
</pre>
 
==== WDC WD2003FYYS-02W0B0 2TB ====
 
==== WDC WD2003FYYS-02W0B0 2TB ====
 
<pre>
 
<pre>

Revision as of 18:20, 10 October 2017

This page is meant to contain smartctl information for assorted drives, so people can look and see whether ERC etc is supported. It's quite hard to find out information from marketing information.

Please create the section header for a drive as the model number, year of purchase in brackets if known, and capacity.

The data should be the output of "smartctl -x" - for non-raid drives you may need to do "smartctl -s on /dev/sdX" to get the output as cheaper drives forget settings between reboots.

Drives are classified as "raid" or "non-raid" depending on whether they support SCT/ERC.

Contents

Hitachi Drives

Raid drives

Hitachi/HGST Ultrastar 7K4000

HGST HUS724020ALA640 (2TB)

smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.9.0-4-amd64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Hitachi/HGST Ultrastar 7K4000
Device Model:     HGST HUS724020ALA640
Serial Number:    PN1138P2GJ8MYH
LU WWN Device Id: 5 000cca 24bc76662
Firmware Version: MF6OAA70
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Tue Oct 10 10:31:21 2017 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Disabled
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (  41)	The self-test routine was interrupted
					by the host with a hard or soft reset.
Total time to complete Offline 
data collection: 		(   28) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 328) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     PO-R--   100   100   016    -    0
  2 Throughput_Performance  P-S---   137   137   054    -    78
  3 Spin_Up_Time            POS---   149   149   024    -    434 (Average 402)
  4 Start_Stop_Count        -O--C-   100   100   000    -    18
  5 Reallocated_Sector_Ct   PO--CK   100   100   005    -    0
  7 Seek_Error_Rate         PO-R--   100   100   067    -    0
  8 Seek_Time_Performance   P-S---   142   142   020    -    25
  9 Power_On_Hours          -O--C-   098   098   000    -    15240
 10 Spin_Retry_Count        PO--C-   100   100   060    -    0
 12 Power_Cycle_Count       -O--CK   100   100   000    -    18
192 Power-Off_Retract_Count -O--CK   100   100   000    -    403
193 Load_Cycle_Count        -O--C-   100   100   000    -    403
194 Temperature_Celsius     -O----   166   166   000    -    36 (Min/Max 23/49)
196 Reallocated_Event_Count -O--CK   100   100   000    -    0
197 Current_Pending_Sector  -O---K   100   100   000    -    0
198 Offline_Uncorrectable   ---R--   100   100   000    -    0
199 UDMA_CRC_Error_Count    -O-R--   200   200   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x03       GPL     R/O      1  Ext. Comprehensive SMART error log
0x04       GPL     R/O      7  Device Statistics log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x08       GPL     R/O      2  Power Conditions log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  SATA NCQ Queued Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x20       GPL     R/O      1  Streaming performance log [OBS-8]
0x21       GPL     R/O      1  Write stream error log
0x22       GPL     R/O      1  Read stream error log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Interrupted (host reset)      90%     14493         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       256 (0x0100)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    36 Celsius
Power Cycle Min/Max Temperature:     35/40 Celsius
Lifetime    Min/Max Temperature:     23/49 Celsius
Under/Over Temperature Limit Count:   0/0

SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:      0/60 Celsius
Min/Max Temperature Limit:           -40/70 Celsius
Temperature History Size (Index):    128 (96)

Index    Estimated Time   Temperature Celsius
  97    2017-10-10 08:24    36  *****************
 ...    ..(126 skipped).    ..  *****************
  96    2017-10-10 10:31    36  *****************

SCT Error Recovery Control:
           Read: Disabled
          Write: Disabled

Device Statistics (GP Log 0x04)
Page  Offset Size        Value Flags Description
0x01  =====  =               =  ===  == General Statistics (rev 2) ==
0x01  0x008  4              18  ---  Lifetime Power-On Resets
0x01  0x018  6    353645484537  ---  Logical Sectors Written
0x01  0x020  6     13505157115  ---  Number of Write Commands
0x01  0x028  6    319592434652  ---  Logical Sectors Read
0x01  0x030  6      2292219761  ---  Number of Read Commands
0x03  =====  =               =  ===  == Rotating Media Statistics (rev 1) ==
0x03  0x008  4           15238  ---  Spindle Motor Power-on Hours
0x03  0x010  4           15238  ---  Head Flying Hours
0x03  0x018  4             403  ---  Head Load Events
0x03  0x020  4               0  ---  Number of Reallocated Logical Sectors
0x03  0x028  4               2  ---  Read Recovery Attempts
0x03  0x030  4               0  ---  Number of Mechanical Start Failures
0x04  =====  =               =  ===  == General Errors Statistics (rev 1) ==
0x04  0x008  4               0  ---  Number of Reported Uncorrectable Errors
0x04  0x010  4               0  ---  Resets Between Cmd Acceptance and Completion
0x05  =====  =               =  ===  == Temperature Statistics (rev 1) ==
0x05  0x008  1              36  ---  Current Temperature
0x05  0x010  1              36  N--  Average Short Term Temperature
0x05  0x018  1              37  N--  Average Long Term Temperature
0x05  0x020  1              49  ---  Highest Temperature
0x05  0x028  1              23  ---  Lowest Temperature
0x05  0x030  1              44  N--  Highest Average Short Term Temperature
0x05  0x038  1              25  N--  Lowest Average Short Term Temperature
0x05  0x040  1              40  N--  Highest Average Long Term Temperature
0x05  0x048  1              25  N--  Lowest Average Long Term Temperature
0x05  0x050  4               0  ---  Time in Over-Temperature
0x05  0x058  1              60  ---  Specified Maximum Operating Temperature
0x05  0x060  4               0  ---  Time in Under-Temperature
0x05  0x068  1               0  ---  Specified Minimum Operating Temperature
0x06  =====  =               =  ===  == Transport Statistics (rev 1) ==
0x06  0x008  4             234  ---  Number of Hardware Resets
0x06  0x010  4             209  ---  Number of ASR Events
0x06  0x018  4               0  ---  Number of Interface CRC Errors
                                |||_ C monitored condition met
                                ||__ D supports DSN
                                |___ N normalized value

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error

HGST HUS726060ALE610 (6TB)

smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     HGST HUS726060ALE610
Serial Number:    NAHSHAAX
LU WWN Device Id: 5 000cca 242d8c599
Firmware Version: APGNT7J0
User Capacity:    6,001,175,126,016 bytes [6.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Form Factor:      3.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Tue Oct 10 12:14:03 2017 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM level is:     254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  113) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 752) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     PO-R--   100   100   016    -    0
  2 Throughput_Performance  P-S---   138   138   054    -    100
  3 Spin_Up_Time            POS---   100   100   024    -    0
  4 Start_Stop_Count        -O--C-   100   100   000    -    6
  5 Reallocated_Sector_Ct   PO--CK   100   100   005    -    0
  7 Seek_Error_Rate         PO-R--   100   100   067    -    0
  8 Seek_Time_Performance   P-S---   136   136   020    -    16
  9 Power_On_Hours          -O--C-   098   098   000    -    16085
 10 Spin_Retry_Count        PO--C-   100   100   060    -    0
 12 Power_Cycle_Count       -O--CK   100   100   000    -    6
192 Power-Off_Retract_Count -O--CK   100   100   000    -    672
193 Load_Cycle_Count        -O--C-   100   100   000    -    672
194 Temperature_Celsius     -O----   200   200   000    -    30 (Min/Max 19/36)
196 Reallocated_Event_Count -O--CK   100   100   000    -    0
197 Current_Pending_Sector  -O---K   100   100   000    -    0
198 Offline_Uncorrectable   ---R--   100   100   000    -    0
199 UDMA_CRC_Error_Count    -O-R--   200   200   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      1  Comprehensive SMART error log
0x03       GPL     R/O      1  Ext. Comprehensive SMART error log
0x04       GPL,SL  R/O      8  Device Statistics log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x08       GPL     R/O      2  Power Conditions log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  SATA NCQ Queued Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x12       GPL     R/O      1  SATA NCQ NON-DATA log
0x15       GPL,SL  R/W      1  SATA Rebuild Assist log
0x21       GPL     R/O      1  Write stream error log
0x22       GPL     R/O      1  Read stream error log
0x24       GPL     R/O    256  Current Device Internal Status Data log
0x25       GPL     R/O    256  Saved Device Internal Status Data log
0x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%     15954         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       256 (0x0100)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    30 Celsius
Power Cycle Min/Max Temperature:     25/33 Celsius
Lifetime    Min/Max Temperature:     19/36 Celsius
Under/Over Temperature Limit Count:   0/0

SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:      0/60 Celsius
Min/Max Temperature Limit:           -40/70 Celsius
Temperature History Size (Index):    128 (79)

Index    Estimated Time   Temperature Celsius
  80    2017-10-10 10:07    30  ***********

SCT Error Recovery Control:
           Read: Disabled
          Write: Disabled

Device Statistics (GP Log 0x04)
Page Offset Size         Value  Description
  1  =====  =                =  == General Statistics (rev 2) ==
  1  0x008  4                6  Lifetime Power-On Resets
  1  0x018  6       6837083432  Logical Sectors Written
  1  0x020  6         18033121  Number of Write Commands
  1  0x028  6     103037210207  Logical Sectors Read
  1  0x030  6         84755469  Number of Read Commands
  1  0x038  6      57908116650  Date and Time TimeStamp
  3  =====  =                =  == Rotating Media Statistics (rev 1) ==
  3  0x008  4            16065  Spindle Motor Power-on Hours
  3  0x010  4            16065  Head Flying Hours
  3  0x018  4              672  Head Load Events
  3  0x020  4                0  Number of Reallocated Logical Sectors
  3  0x028  4          1904036  Read Recovery Attempts
  3  0x030  4                0  Number of Mechanical Start Failures
  4  =====  =                =  == General Errors Statistics (rev 1) ==
  4  0x008  4                0  Number of Reported Uncorrectable Errors
  4  0x010  4                0  Resets Between Cmd Acceptance and Completion
  5  =====  =                =  == Temperature Statistics (rev 1) ==
  5  0x008  1               30  Current Temperature
  5  0x010  1               30~ Average Short Term Temperature
  5  0x018  1               29~ Average Long Term Temperature
  5  0x020  1               36  Highest Temperature
  5  0x028  1               19  Lowest Temperature
  5  0x030  1               34~ Highest Average Short Term Temperature
  5  0x038  1               25~ Lowest Average Short Term Temperature
  5  0x040  1               32~ Highest Average Long Term Temperature
  5  0x048  1               25~ Lowest Average Long Term Temperature
  5  0x050  4                0  Time in Over-Temperature
  5  0x058  1               60  Specified Maximum Operating Temperature
  5  0x060  4                0  Time in Under-Temperature
  5  0x068  1                0  Specified Minimum Operating Temperature
  6  =====  =                =  == Transport Statistics (rev 1) ==
  6  0x008  4                7  Number of Hardware Resets
  6  0x010  4                0  Number of ASR Events
  6  0x018  4                0  Number of Interface CRC Errors
                              |_ ~ normalized value

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error

Hitachi UltraStar

HUS726020ALA610 2TB

smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     HUS726020ALA610
Serial Number:    K5GAEXJA
LU WWN Device Id: 5 000cca 25ec4bff7
Firmware Version: T7R4
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Form Factor:      3.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Tue Oct 10 10:13:46 2017 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM level is:     254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  113) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 288) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     PO-R--   100   100   016    -    0
  2 Throughput_Performance  P-S---   134   134   054    -    116
  3 Spin_Up_Time            POS---   134   134   024    -    222 (Average 222)
  4 Start_Stop_Count        -O--C-   100   100   000    -    22
  5 Reallocated_Sector_Ct   PO--CK   100   100   005    -    0
  7 Seek_Error_Rate         PO-R--   100   100   067    -    0
  8 Seek_Time_Performance   P-S---   128   128   020    -    18
  9 Power_On_Hours          -O--C-   100   100   000    -    6927
 10 Spin_Retry_Count        PO--C-   100   100   060    -    0
 12 Power_Cycle_Count       -O--CK   100   100   000    -    22
192 Power-Off_Retract_Count -O--CK   100   100   000    -    308
193 Load_Cycle_Count        -O--C-   100   100   000    -    308
194 Temperature_Celsius     -O----   187   187   000    -    32 (Min/Max 14/42)
196 Reallocated_Event_Count -O--CK   100   100   000    -    0
197 Current_Pending_Sector  -O---K   100   100   000    -    0
198 Offline_Uncorrectable   ---R--   100   100   000    -    0
199 UDMA_CRC_Error_Count    -O-R--   200   200   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      1  Comprehensive SMART error log
0x03       GPL     R/O      1  Ext. Comprehensive SMART error log
0x04       GPL,SL  R/O      8  Device Statistics log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x08       GPL     R/O      2  Power Conditions log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  SATA NCQ Queued Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x12       GPL     R/O      1  SATA NCQ NON-DATA log
0x15       GPL,SL  R/W      1  SATA Rebuild Assist log
0x21       GPL     R/O      1  Write stream error log
0x22       GPL     R/O      1  Read stream error log
0x24       GPL     R/O    256  Current Device Internal Status Data log
0x25       GPL     R/O    256  Saved Device Internal Status Data log
0x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xb2       GPL     VS     688  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%      6877         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       256 (0x0100)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    32 Celsius
Power Cycle Min/Max Temperature:     29/35 Celsius
Lifetime    Min/Max Temperature:     14/42 Celsius
Under/Over Temperature Limit Count:   0/0

SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:      0/60 Celsius
Min/Max Temperature Limit:           -40/70 Celsius
Temperature History Size (Index):    128 (91)

Index    Estimated Time   Temperature Celsius
  92    2017-10-10 08:06    32  *************
 ...    ..(126 skipped).    ..  *************
  91    2017-10-10 10:13    32  *************

SCT Error Recovery Control:
           Read: Disabled
          Write: Disabled

Device Statistics (GP Log 0x04)
Page Offset Size         Value  Description
  1  =====  =                =  == General Statistics (rev 2) ==
  1  0x008  4               22  Lifetime Power-On Resets
  1  0x018  6      30112514255  Logical Sectors Written
  1  0x020  6        271980557  Number of Write Commands
  1  0x028  6        979589491  Logical Sectors Read
  1  0x030  6          6488861  Number of Read Commands
  1  0x038  6      24938295750  Date and Time TimeStamp
  3  =====  =                =  == Rotating Media Statistics (rev 1) ==
  3  0x008  4             6866  Spindle Motor Power-on Hours
  3  0x010  4             6866  Head Flying Hours
  3  0x018  4              308  Head Load Events
  3  0x020  4                0  Number of Reallocated Logical Sectors
  3  0x028  4             9482  Read Recovery Attempts
  3  0x030  4                0  Number of Mechanical Start Failures
  4  =====  =                =  == General Errors Statistics (rev 1) ==
  4  0x008  4                0  Number of Reported Uncorrectable Errors
  4  0x010  4                0  Resets Between Cmd Acceptance and Completion
  5  =====  =                =  == Temperature Statistics (rev 1) ==
  5  0x008  1               32  Current Temperature
  5  0x010  1               32~ Average Short Term Temperature
  5  0x018  1               31~ Average Long Term Temperature
  5  0x020  1               42  Highest Temperature
  5  0x028  1               14  Lowest Temperature
  5  0x030  1               40~ Highest Average Short Term Temperature
  5  0x038  1               25~ Lowest Average Short Term Temperature
  5  0x040  1               37~ Highest Average Long Term Temperature
  5  0x048  1               25~ Lowest Average Long Term Temperature
  5  0x050  4                0  Time in Over-Temperature
  5  0x058  1               60  Specified Maximum Operating Temperature
  5  0x060  4                0  Time in Under-Temperature
  5  0x068  1                0  Specified Minimum Operating Temperature
  6  =====  =                =  == Transport Statistics (rev 1) ==
  6  0x008  4               14  Number of Hardware Resets
  6  0x010  4               22  Number of ASR Events
  6  0x018  4                0  Number of Interface CRC Errors
                              |_ ~ normalized value

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error

Hitachi Ultrastar 7K3000

Hitachi HUA723030ALA640 3TB

smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Hitachi Ultrastar 7K3000
Device Model:     Hitachi HUA723030ALA640
Serial Number:    MK0331YHH2R1BA
LU WWN Device Id: 5 000cca 225cf52ff
Firmware Version: MKAOA800
User Capacity:    3,000,592,982,016 bytes [3.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Tue Oct 10 11:12:40 2017 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Disabled
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x84)	Offline data collection activity
					was suspended by an interrupting command from host.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(29746) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 496) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     PO-R--   100   100   016    -    0
  2 Throughput_Performance  P-S---   135   135   054    -    85
  3 Spin_Up_Time            POS---   100   100   024    -    506
  4 Start_Stop_Count        -O--C-   100   100   000    -    14
  5 Reallocated_Sector_Ct   PO--CK   100   100   005    -    0
  7 Seek_Error_Rate         PO-R--   100   100   067    -    0
  8 Seek_Time_Performance   P-S---   138   138   020    -    25
  9 Power_On_Hours          -O--C-   093   093   000    -    50018
 10 Spin_Retry_Count        PO--C-   100   100   060    -    0
 12 Power_Cycle_Count       -O--CK   100   100   000    -    14
192 Power-Off_Retract_Count -O--CK   099   099   000    -    1512
193 Load_Cycle_Count        -O--C-   099   099   000    -    1512
194 Temperature_Celsius     -O----   222   222   000    -    27 (Min/Max 17/41)
196 Reallocated_Event_Count -O--CK   100   100   000    -    0
197 Current_Pending_Sector  -O---K   100   100   000    -    0
198 Offline_Uncorrectable   ---R--   100   100   000    -    0
199 UDMA_CRC_Error_Count    -O-R--   200   200   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x03       GPL     R/O      1  Ext. Comprehensive SMART error log
0x04       GPL     R/O      7  Device Statistics log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x08       GPL     R/O      2  Power Conditions log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  SATA NCQ Queued Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x20       GPL     R/O      1  Streaming performance log [OBS-8]
0x21       GPL     R/O      1  Write stream error log
0x22       GPL     R/O      1  Read stream error log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%     49968         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       256 (0x0100)
SCT Support Level:                   1
Device State:                        SMART Off-line Data Collection executing in background (4)
Current Temperature:                    27 Celsius
Power Cycle Min/Max Temperature:     24/39 Celsius
Lifetime    Min/Max Temperature:     17/41 Celsius
Under/Over Temperature Limit Count:   0/0

SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:      0/60 Celsius
Min/Max Temperature Limit:           -40/70 Celsius
Temperature History Size (Index):    128 (69)

Index    Estimated Time   Temperature Celsius
  70    2017-10-10 09:05    27  ********

SCT Error Recovery Control:
           Read: Disabled
          Write: Disabled

Device Statistics (GP Log 0x04)
Page Offset Size         Value  Description
  1  =====  =                =  == General Statistics (rev 1) ==
  1  0x008  4               14  Lifetime Power-On Resets
  1  0x010  4            50018  Power-on Hours
  1  0x018  6      17970047602  Logical Sectors Written
  1  0x020  6        204753509  Number of Write Commands
  1  0x028  6     420723716215  Logical Sectors Read
  1  0x030  6      12875958968  Number of Read Commands
  3  =====  =                =  == Rotating Media Statistics (rev 1) ==
  3  0x008  4            50010  Spindle Motor Power-on Hours
  3  0x010  4            50010  Head Flying Hours
  3  0x018  4             1512  Head Load Events
  3  0x020  4                0  Number of Reallocated Logical Sectors
  3  0x028  4               23  Read Recovery Attempts
  3  0x030  4                0  Number of Mechanical Start Failures
  4  =====  =                =  == General Errors Statistics (rev 1) ==
  4  0x008  4                0  Number of Reported Uncorrectable Errors
  4  0x010  4                0  Resets Between Cmd Acceptance and Completion
  5  =====  =                =  == Temperature Statistics (rev 1) ==
  5  0x008  1               27  Current Temperature
  5  0x010  1               26~ Average Short Term Temperature
  5  0x018  1               26~ Average Long Term Temperature
  5  0x020  1               41  Highest Temperature
  5  0x028  1               17  Lowest Temperature
  5  0x030  1               33~ Highest Average Short Term Temperature
  5  0x038  1               25~ Lowest Average Short Term Temperature
  5  0x040  1               32~ Highest Average Long Term Temperature
  5  0x048  1               25~ Lowest Average Long Term Temperature
  5  0x050  4                0  Time in Over-Temperature
  5  0x058  1               60  Specified Maximum Operating Temperature
  5  0x060  4                0  Time in Under-Temperature
  5  0x068  1                0  Specified Minimum Operating Temperature
  6  =====  =                =  == Transport Statistics (rev 1) ==
  6  0x008  4               29  Number of Hardware Resets
  6  0x010  4               21  Number of ASR Events
  6  0x018  4                0  Number of Interface CRC Errors
                              |_ ~ normalized value

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error

Non-Raid drives

Samsung drives

Raid drives

SAMSUNG MZ7KM480HAHP-00005

smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     SAMSUNG MZ7KM480HAHP-00005
Serial Number:    S2HSNX0H801784
LU WWN Device Id: 5 002538 c403a4fbc
Firmware Version: GXM1003Q
User Capacity:    480,103,981,056 bytes [480 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Tue Oct 10 10:13:39 2017 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		( 2100) seconds.
Offline data collection
capabilities: 			 (0x53) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					No Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 (  35) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  5 Reallocated_Sector_Ct   PO--CK   100   100   010    -    0
  9 Power_On_Hours          -O--CK   098   098   000    -    6523
 12 Power_Cycle_Count       -O--CK   099   099   000    -    13
177 Wear_Leveling_Count     PO--C-   099   099   005    -    7
179 Used_Rsvd_Blk_Cnt_Tot   PO--C-   100   100   010    -    0
180 Unused_Rsvd_Blk_Cnt_Tot PO--C-   100   100   010    -    3837
181 Program_Fail_Cnt_Total  -O--CK   100   100   010    -    0
182 Erase_Fail_Count_Total  -O--CK   100   100   010    -    0
183 Runtime_Bad_Block       PO--C-   100   100   010    -    0
184 End-to-End_Error        PO--CK   100   100   097    -    0
187 Reported_Uncorrect      -O--CK   100   100   000    -    0
190 Airflow_Temperature_Cel -O--CK   065   059   000    -    35
195 Hardware_ECC_Recovered  -O-RC-   200   200   000    -    0
197 Current_Pending_Sector  -O--CK   100   100   000    -    0
199 UDMA_CRC_Error_Count    -OSRCK   100   100   000    -    0
202 Unknown_SSD_Attribute   PO--CK   100   100   010    -    0
235 Unknown_Attribute       -O--C-   099   099   000    -    8
241 Total_LBAs_Written      -O--CK   099   099   000    -    744789435
242 Total_LBAs_Read         -O--CK   099   099   000    -    141692277
243 Unknown_Attribute       -O--CK   100   100   000    -    0
244 Unknown_Attribute       -O--CK   100   100   000    -    0
245 Unknown_Attribute       -O--CK   100   100   000    -    65535
246 Unknown_Attribute       -O--CK   100   100   000    -    65535
247 Unknown_Attribute       -O--CK   100   100   000    -    65535
251 Unknown_Attribute       -O--CK   100   100   000    -    10942216040
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      1  Comprehensive SMART error log
0x03       GPL     R/O      1  Ext. Comprehensive SMART error log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  SATA NCQ Queued Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x13       GPL     R/O      1  SATA NCQ Send and Receive log
0x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xce           SL  VS      16  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%      6466         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
  255        0    65535  Read_scanning was completed without error
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       256 (0x0100)
SCT Support Level:                   1
Device State:                        SCT command executing in background (5)
Current Temperature:                    35 Celsius
Power Cycle Min/Max Temperature:     32/38 Celsius
Lifetime    Min/Max Temperature:      0/70 Celsius
Under/Over Temperature Limit Count:  4294967295/4294967295

SCT Temperature History Version:     3 (Unknown, should be 2)
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        10 minutes
Min/Max recommended Temperature:      0/70 Celsius
Min/Max Temperature Limit:            0/70 Celsius
Temperature History Size (Index):    128 (88)

Index    Estimated Time   Temperature Celsius
  89    2017-10-09 13:00    34  ***************

SCT Error Recovery Control:
           Read: Disabled
          Write: Disabled

Device Statistics (GP/SMART Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error
0x0002  2            0  R_ERR response for data FIS
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0005  2            0  R_ERR response for non-data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x0008  2            0  Device-to-host non-data FIS retries
0x0009  2           19  Transition from drive PhyRdy to drive PhyNRdy
0x000a  2           19  Device-to-host register FISes sent due to a COMRESET
0x000b  2            0  CRC errors within host-to-device FIS
0x000d  2            0  Non-CRC errors within host-to-device FIS
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
0x0010  2            0  R_ERR response for host-to-device data FIS, non-CRC
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
0x0013  2            0  R_ERR response for host-to-device non-data FIS, non-CRC

SAMSUNG MZ7LN128HCHP-00000

smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     SAMSUNG MZ7LN128HCHP-00000
Serial Number:    S1ZFNXAG652991
LU WWN Device Id: 5 002538 d40286c3d
Firmware Version: EMT0100Q
User Capacity:    128,035,676,160 bytes [128 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Tue Oct 10 12:14:03 2017 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(    0) seconds.
Offline data collection
capabilities: 			 (0x53) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					No Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 (  64) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  5 Reallocated_Sector_Ct   PO--CK   100   100   010    -    0
  9 Power_On_Hours          -O--CK   096   096   000    -    16093
 12 Power_Cycle_Count       -O--CK   099   099   000    -    7
170 Unknown_Attribute       -O--CK   100   100   010    -    0
171 Unknown_Attribute       -O--CK   100   100   010    -    0
172 Unknown_Attribute       -O--CK   100   100   010    -    0
173 Unknown_Attribute       PO--CK   097   097   005    -    52
174 Unknown_Attribute       -O--CK   099   099   000    -    3
178 Used_Rsvd_Blk_Cnt_Chip  PO--C-   100   100   010    -    0
180 Unused_Rsvd_Blk_Cnt_Tot PO--C-   100   100   010    -    325
184 End-to-End_Error        PO--CK   100   100   097    -    0
187 Reported_Uncorrect      -O--CK   100   100   000    -    0
194 Temperature_Celsius     -O--CK   068   055   000    -    32
199 UDMA_CRC_Error_Count    -OSRCK   100   100   000    -    0
233 Media_Wearout_Indicator PO--C-   097   097   000    -    16341007
241 Total_LBAs_Written      -O--CK   099   099   000    -    2219
242 Total_LBAs_Read         -O--CK   099   099   000    -    5
249 Unknown_Attribute       -O--CK   099   099   000    -    6688
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      1  Comprehensive SMART error log
0x03       GPL     R/O      1  Ext. Comprehensive SMART error log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  SATA NCQ Queued Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x13       GPL     R/O      1  SATA NCQ Send and Receive log
0x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xdf       GPL,SL  VS       1  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%     15950         -

Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
  255        0    65535  Read_scanning was never started
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       256 (0x0100)
SCT Support Level:                   1
Device State:                        SCT command executing in background (5)
Current Temperature:                    32 Celsius
Power Cycle Min/Max Temperature:     30/45 Celsius
Lifetime    Min/Max Temperature:      0/70 Celsius
Under/Over Temperature Limit Count:  1048576/0

SCT Temperature History Version:     3 (Unknown, should be 2)
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        10 minutes
Min/Max recommended Temperature:      0/70 Celsius
Min/Max Temperature Limit:            0/70 Celsius
Temperature History Size (Index):    128 (77)

Index    Estimated Time   Temperature Celsius
  77    2017-10-10 12:10    32  *************

SCT Error Recovery Control:
           Read: Disabled
          Write: Disabled

Device Statistics (GP/SMART Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error
0x0002  2            0  R_ERR response for data FIS
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0005  2            0  R_ERR response for non-data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x0008  2            0  Device-to-host non-data FIS retries
0x0009  2           19  Transition from drive PhyRdy to drive PhyNRdy
0x000a  2           19  Device-to-host register FISes sent due to a COMRESET
0x000b  2            0  CRC errors within host-to-device FIS
0x000d  2            0  Non-CRC errors within host-to-device FIS
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
0x0010  2            0  R_ERR response for host-to-device data FIS, non-CRC
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
0x0013  2            0  R_ERR response for host-to-device non-data FIS, non-CRC

Non-Raid drives

Seagate drives

Raid drives

Seagate NAS

Seagate Ironwolf

Seagate Constellation

ST2000NM0033-9ZM175 (2TB)

smartctl 5.41 2011-06-09 r3365 [x86_64-linux-2.6.32-openvz-042stab123.8-amd64] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     ST2000NM0033-9ZM175
Serial Number:    Z1Y0MAX4
LU WWN Device Id: 5 000c50 064b09f28
Firmware Version: SN03
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   9
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Tue Oct 10 10:29:06 2017 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  592) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 246) minutes.
Conveyance self-test routine
recommended polling time: 	 (   2) minutes.
SCT capabilities: 	       (0x50bd)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR--   084   063   044    -    2318897
  3 Spin_Up_Time            PO----   094   094   000    -    0
  4 Start_Stop_Count        -O--CK   100   100   020    -    9
  5 Reallocated_Sector_Ct   PO--CK   100   100   010    -    0
  7 Seek_Error_Rate         POSR--   095   060   030    -    3348031798
  9 Power_On_Hours          -O--CK   061   061   000    -    34301
 10 Spin_Retry_Count        PO--C-   100   100   097    -    0
 12 Power_Cycle_Count       -O--CK   100   100   020    -    9
184 End-to-End_Error        -O--CK   100   100   099    -    0
187 Reported_Uncorrect      -O--CK   100   100   000    -    0
188 Command_Timeout         -O--CK   100   100   000    -    0
189 High_Fly_Writes         -O-RCK   100   100   000    -    0
190 Airflow_Temperature_Cel -O---K   068   061   045    -    32 (Min/Max 23/39)
191 G-Sense_Error_Rate      -O--CK   100   100   000    -    0
192 Power-Off_Retract_Count -O--CK   100   100   000    -    6
193 Load_Cycle_Count        -O--CK   100   100   000    -    1458
194 Temperature_Celsius     -O---K   032   040   000    -    32 (0 22 0 0)
195 Hardware_ECC_Recovered  -O-RC-   043   009   000    -    2318897
197 Current_Pending_Sector  -O--C-   100   100   000    -    0
198 Offline_Uncorrectable   ----C-   100   100   000    -    0
199 UDMA_CRC_Error_Count    -OSRCK   200   200   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
GP/S  Log at address 0x00 has    1 sectors [Log Directory]
SMART Log at address 0x01 has    1 sectors [Summary SMART error log]
SMART Log at address 0x02 has    5 sectors [Comprehensive SMART error log]
GP    Log at address 0x03 has    5 sectors [Ext. Comprehensive SMART error log]
SMART Log at address 0x06 has    1 sectors [SMART self-test log]
GP    Log at address 0x07 has    1 sectors [Extended self-test log]
GP/S  Log at address 0x08 has    2 sectors [Power Conditions]
SMART Log at address 0x09 has    1 sectors [Selective self-test log]
GP    Log at address 0x10 has    1 sectors [NCQ Command Error]
GP    Log at address 0x11 has    1 sectors [SATA Phy Event Counters]
GP    Log at address 0x21 has    1 sectors [Write stream error log]
GP    Log at address 0x22 has    1 sectors [Read stream error log]
GP/S  Log at address 0x30 has    9 sectors [Reserved]
GP/S  Log at address 0x80 has   16 sectors [Host vendor specific log]
GP/S  Log at address 0xe0 has    1 sectors [SCT Command/Status]
GP/S  Log at address 0xe1 has    1 sectors [SCT Data Transfer]

SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%     25207         -
# 2  Extended offline    Completed without error       00%     12345         -
# 3  Extended offline    Completed without error       00%       879         -
# 4  Extended offline    Completed without error       00%         3         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       522 (0x020a)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    32 Celsius
Power Cycle Min/Max Temperature:     23/39 Celsius
Lifetime    Min/Max Temperature:     22/39 Celsius
Under/Over Temperature Limit Count:   0/205519
SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        10 minutes
Min/Max recommended Temperature:      0/ 0 Celsius
Min/Max Temperature Limit:            0/ 0 Celsius
Temperature History Size (Index):    128 (18)

Index    Estimated Time   Temperature Celsius
  19    2017-10-09 13:10    32  *************
 ...    ..(126 skipped).    ..  *************
  18    2017-10-10 10:20    32  *************

SCT Error Recovery Control:
           Read:    100 (10.0 seconds)
          Write:    100 (10.0 seconds)

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x000a  2          115  Device-to-host register FISes sent due to a COMRESET
0x0001  2            0  Command failed due to ICRC error
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS

ST91000640NS (1TB)

smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.16.0-0.bpo.4-amd64] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     ST91000640NS
Serial Number:    9XG4ZBZJ
LU WWN Device Id: 5 000c50 064438461
Firmware Version: SN03
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Tue Oct 10 12:16:17 2017 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  642) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 203) minutes.
Conveyance self-test routine
recommended polling time: 	 (   2) minutes.
SCT capabilities: 	       (0x10bd)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR--   079   064   044    -    91112581
  3 Spin_Up_Time            PO----   094   094   000    -    0
  4 Start_Stop_Count        -O--CK   100   100   020    -    11
  5 Reallocated_Sector_Ct   PO--CK   100   100   036    -    0
  7 Seek_Error_Rate         POSR--   078   060   030    -    67076501
  9 Power_On_Hours          -O--CK   074   074   000    -    23393
 10 Spin_Retry_Count        PO--C-   100   100   097    -    0
 12 Power_Cycle_Count       -O--CK   100   100   020    -    11
184 End-to-End_Error        -O--CK   100   100   099    -    0
187 Reported_Uncorrect      -O--CK   100   100   000    -    0
188 Command_Timeout         -O--CK   100   100   000    -    0
189 High_Fly_Writes         -O-RCK   100   100   000    -    0
190 Airflow_Temperature_Cel -O---K   063   053   045    -    37 (Min/Max 29/47)
191 G-Sense_Error_Rate      -O--CK   100   100   000    -    0
192 Power-Off_Retract_Count -O--CK   100   100   000    -    7
193 Load_Cycle_Count        -O--CK   100   100   000    -    13
194 Temperature_Celsius     -O---K   037   047   000    -    37 (0 19 0 0)
195 Hardware_ECC_Recovered  -O-RC-   115   100   000    -    91112581
197 Current_Pending_Sector  -O--C-   100   100   000    -    0
198 Offline_Uncorrectable   ----C-   100   100   000    -    0
199 UDMA_CRC_Error_Count    -OSRCK   200   200   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
GP/S  Log at address 0x00 has    1 sectors [Log Directory]
SMART Log at address 0x01 has    1 sectors [Summary SMART error log]
SMART Log at address 0x02 has    5 sectors [Comprehensive SMART error log]
GP    Log at address 0x03 has    5 sectors [Ext. Comprehensive SMART error log]
SMART Log at address 0x06 has    1 sectors [SMART self-test log]
GP    Log at address 0x07 has    1 sectors [Extended self-test log]
SMART Log at address 0x09 has    1 sectors [Selective self-test log]
GP    Log at address 0x10 has    1 sectors [NCQ Command Error]
GP    Log at address 0x11 has    1 sectors [SATA Phy Event Counters]
GP/S  Log at address 0x12 has    1 sectors [Reserved for Serial ATA]
GP    Log at address 0x21 has    1 sectors [Write stream error log]
GP    Log at address 0x22 has    1 sectors [Read stream error log]
GP/S  Log at address 0x80 has   16 sectors [Host vendor specific log]
GP    Log at address 0xbf has 65535 sectors [Device vendor specific log]
GP/S  Log at address 0xe0 has    1 sectors [SCT Command/Status]
GP/S  Log at address 0xe1 has    1 sectors [SCT Data Transfer]

SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       522 (0x020a)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    37 Celsius
Power Cycle Min/Max Temperature:     29/47 Celsius
Lifetime    Min/Max Temperature:     19/54 Celsius
Under/Over Temperature Limit Count:   0/138619
SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        10 minutes
Min/Max recommended Temperature:      0/ 0 Celsius
Min/Max Temperature Limit:            0/ 0 Celsius
Temperature History Size (Index):    128 (106)

Index    Estimated Time   Temperature Celsius
 106    2017-10-10 12:10    37  ******************

SCT Error Recovery Control:
           Read:    100 (10.0 seconds)
          Write:    100 (10.0 seconds)

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x000a  2          103  Device-to-host register FISes sent due to a COMRESET
0x0001  2            0  Command failed due to ICRC error
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS

Seagate Samsung Spinpoint

ST2000LM003 (2016) 2 TB

smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.4.79-19-default] (SUSE RPM)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Samsung SpinPoint M9T
Device Model:     ST2000LM003 HN-M201RAD
Serial Number:    S321J9DG805231
LU WWN Device Id: 5 0004cf 2106b38eb
Firmware Version: 2BC10001
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Form Factor:      2.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Mon Sep  4 19:57:01 2017 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Disabled
APM feature is:   Disabled
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (  40)	The self-test routine was interrupted
					by the host with a hard or soft reset.
Total time to complete Offline 
data collection: 		(22740) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 379) minutes.
SCT capabilities: 	       (0x003f)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR-K   100   100   051    -    0
  2 Throughput_Performance  -OS--K   252   252   000    -    0
  3 Spin_Up_Time            PO---K   092   092   025    -    2555
  4 Start_Stop_Count        -O--CK   100   100   000    -    763
  5 Reallocated_Sector_Ct   PO--CK   252   252   010    -    0
  7 Seek_Error_Rate         -OSR-K   252   252   051    -    0
  8 Seek_Time_Performance   --S--K   252   252   015    -    0
  9 Power_On_Hours          -O--CK   100   100   000    -    1169
 10 Spin_Retry_Count        -O--CK   252   252   051    -    0
 12 Power_Cycle_Count       -O--CK   100   100   000    -    794
191 G-Sense_Error_Rate      -O---K   100   100   000    -    13
192 Power-Off_Retract_Count -O---K   252   252   000    -    0
194 Temperature_Celsius     -O----   064   051   000    -    31 (Min/Max 13/49)
195 Hardware_ECC_Recovered  -O-RCK   100   100   000    -    0
196 Reallocated_Event_Count -O--CK   252   252   000    -    0
197 Current_Pending_Sector  -O--CK   252   252   000    -    0
198 Offline_Uncorrectable   ----CK   252   252   000    -    0
199 UDMA_CRC_Error_Count    -OS-CK   200   200   000    -    0
200 Multi_Zone_Error_Rate   -O-R-K   100   100   000    -    11
223 Load_Retry_Count        -O--CK   100   100   000    -    11
225 Load_Cycle_Count        -O--CK   090   090   000    -    107949
241 Total_LBAs_Written      -O--CK   097   094   000    -    4579156
242 Total_LBAs_Read         -O--CK   095   094   000    -    7188547
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      2  Comprehensive SMART error log
0x03       GPL     R/O      2  Ext. Comprehensive SMART error log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      2  Extended self-test log
0x08       GPL     R/O      2  Power Conditions log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  SATA NCQ Queued Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xc0-0xdf  GPL,SL  VS      16  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (2 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Interrupted (host reset)      80%      1169         -
# 2  Extended offline    Interrupted (host reset)      90%      1065         -

SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Interrupted [80% left] (0-65535)
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  2
SCT Version (vendor specific):       256 (0x0100)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    31 Celsius
Power Cycle Min/Max Temperature:     22/31 Celsius
Lifetime    Min/Max Temperature:     13/49 Celsius
Under/Over Temperature Limit Count:   0/0

SCT Temperature History Version:     2
Temperature Sampling Period:         5 minutes
Temperature Logging Interval:        5 minutes
Min/Max recommended Temperature:     -5/80 Celsius
Min/Max Temperature Limit:           -10/85 Celsius
Temperature History Size (Index):    128 (114)

Index    Estimated Time   Temperature Celsius
  46    2017-09-04 14:15    34  ***************

SCT Error Recovery Control:
           Read: Disabled
          Write: Disabled

Device Statistics (GP/SMART Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  4            0  Command failed due to ICRC error
0x0002  4            0  R_ERR response for data FIS

Non-Raid drives

Seagate Barracuda

ST3000DM001 (2014) 3 TB

smartctl 6.4 2015-06-04 r4109 [x86_64-linux-4.4.6-gentoo] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.14 (AF)
Device Model:     ST3000DM001-1CH166
Serial Number:    W1F50K0F
LU WWN Device Id: 5 000c50 0737a98a4
Firmware Version: CC27
User Capacity:    3,000,592,982,016 bytes [3.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Mon Sep  4 16:22:19 2017 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM level is:     128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  592) seconds.
Offline data collection
capabilities:                    (0x73) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 328) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x3085) SCT Status supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR--   115   099   006    -    97112728
  3 Spin_Up_Time            PO----   094   094   000    -    0
  4 Start_Stop_Count        -O--CK   100   100   020    -    260
  5 Reallocated_Sector_Ct   PO--CK   100   100   010    -    0
  7 Seek_Error_Rate         POSR--   076   060   030    -    42637297
  9 Power_On_Hours          -O--CK   085   085   000    -    13787
 10 Spin_Retry_Count        PO--C-   100   100   097    -    0
 12 Power_Cycle_Count       -O--CK   099   099   020    -    1425
183 Runtime_Bad_Block       -O--CK   100   100   000    -    0
184 End-to-End_Error        -O--CK   100   100   099    -    0
187 Reported_Uncorrect      -O--CK   100   100   000    -    0
188 Command_Timeout         -O--CK   100   100   000    -    0 0 2
189 High_Fly_Writes         -O-RCK   100   100   000    -    0
190 Airflow_Temperature_Cel -O---K   055   049   045    -    45 (Min/Max 28/45)
191 G-Sense_Error_Rate      -O--CK   100   100   000    -    0
192 Power-Off_Retract_Count -O--CK   100   100   000    -    28
193 Load_Cycle_Count        -O--CK   098   098   000    -    5774
194 Temperature_Celsius     -O---K   045   051   000    -    45 (0 14 0 0 0)
197 Current_Pending_Sector  -O--C-   100   100   000    -    0
198 Offline_Uncorrectable   ----C-   100   100   000    -    0
199 UDMA_CRC_Error_Count    -OSRCK   200   200   000    -    0
240 Head_Flying_Hours       ------   100   253   000    -    14253h+26m+59.844s
241 Total_LBAs_Written      ------   100   253   000    -    91787618842
242 Total_LBAs_Read         ------   100   253   000    -    3706183336
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      5  Comprehensive SMART error log
0x03       GPL     R/O      5  Ext. Comprehensive SMART error log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  SATA NCQ Queued Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x21       GPL     R/O      1  Write stream error log
0x22       GPL     R/O      1  Read stream error log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa1       GPL,SL  VS      20  Device vendor specific log
0xa2       GPL     VS    4496  Device vendor specific log
0xa8       GPL,SL  VS     129  Device vendor specific log
0xa9       GPL,SL  VS       1  Device vendor specific log
0xab       GPL     VS       1  Device vendor specific log
0xb0       GPL     VS    5176  Device vendor specific log
0xbe-0xbf  GPL     VS   65535  Device vendor specific log
0xc0       GPL,SL  VS       1  Device vendor specific log
0xc1       GPL,SL  VS      10  Device vendor specific log
0xc4       GPL,SL  VS       5  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       522 (0x020a)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    45 Celsius
Power Cycle Min/Max Temperature:     20/45 Celsius
Lifetime    Min/Max Temperature:     13/51 Celsius
Under/Over Temperature Limit Count:   0/0

SCT Data Table command not supported

SCT Error Recovery Control command not supported

Device Statistics (GP/SMART Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x000a  2            2  Device-to-host register FISes sent due to a COMRESET
0x0001  2            0  Command failed due to ICRC error
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS

Toshiba Drives

Raid drives

Toshiba P300 3TB


smartctl 6.2 2013-07-26 r3841 [x86_64-linux-4.4.0-81-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     TOSHIBA HDWD130
Serial Number:    9616Y5XAS
LU WWN Device Id: 5 000039 fe6c327ce
Firmware Version: MX6OACF0
User Capacity:    3,000,592,982,016 bytes [3.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Tue Oct 10 10:51:24 2017 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Disabled
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x84) Offline data collection activity
                                        was suspended by an interrupting command from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (22365) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 373) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     PO-R--   100   100   016    -    0
  2 Throughput_Performance  P-S---   139   139   054    -    71
  3 Spin_Up_Time            POS---   140   140   024    -    391 (Average 430)
  4 Start_Stop_Count        -O--C-   100   100   000    -    27
  5 Reallocated_Sector_Ct   PO--CK   100   100   005    -    0
  7 Seek_Error_Rate         PO-R--   100   100   067    -    0
  8 Seek_Time_Performance   P-S---   124   124   020    -    33
  9 Power_On_Hours          -O--C-   100   100   000    -    6514
 10 Spin_Retry_Count        PO--C-   100   100   060    -    0
 12 Power_Cycle_Count       -O--CK   100   100   000    -    27
192 Power-Off_Retract_Count -O--CK   100   100   000    -    85
193 Load_Cycle_Count        -O--C-   100   100   000    -    85
194 Temperature_Celsius     -O----   125   125   000    -    48 (Min/Max 14/63)
196 Reallocated_Event_Count -O--CK   100   100   000    -    0
197 Current_Pending_Sector  -O---K   100   100   000    -    0
198 Offline_Uncorrectable   ---R--   100   100   000    -    0
199 UDMA_CRC_Error_Count    -O-R--   200   200   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x03       GPL     R/O      1  Ext. Comprehensive SMART error log
0x04       GPL     R/O      7  Device Statistics log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x08       GPL     R/O      2  Power Conditions log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  NCQ Command Error log
0x11       GPL     R/O      1  SATA Phy Event Counters
0x20       GPL     R/O      1  Streaming performance log [OBS-8]
0x21       GPL     R/O      1  Write stream error log
0x22       GPL     R/O      1  Read stream error log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%      6428     -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       256 (0x0100)
SCT Support Level:                   1
Device State:                        SMART Off-line Data Collection executing in background (4)
Current Temperature:                    48 Celsius
Power Cycle Min/Max Temperature:     34/57 Celsius
Lifetime    Min/Max Temperature:     14/63 Celsius
Under/Over Temperature Limit Count:   0/0
SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:      0/60 Celsius
Min/Max Temperature Limit:           -40/70 Celsius
Temperature History Size (Index):    128 (38)

Index    Estimated Time   Temperature Celsius
  39    2017-10-10 08:44    48  *****************************

SCT Error Recovery Control:
           Read:     70 (7.0 seconds)
          Write:     70 (7.0 seconds)

Device Statistics (GP Log 0x04)
Page Offset Size         Value  Description
  1  =====  =                =  == General Statistics (rev 1) ==
  1  0x008  4               27  Lifetime Power-On Resets
  1  0x010  4             6514  Power-on Hours
  1  0x018  6      32561052159  Logical Sectors Written
  1  0x020  6        126298297  Number of Write Commands
  1  0x028  6      86911776569  Logical Sectors Read
  1  0x030  6        114762752  Number of Read Commands
  3  =====  =                =  == Rotating Media Statistics (rev 1) ==
  3  0x008  4             6513  Spindle Motor Power-on Hours
  3  0x010  4             6513  Head Flying Hours
  3  0x018  4               85  Head Load Events
  3  0x020  4                0  Number of Reallocated Logical Sectors
  3  0x028  4                0  Read Recovery Attempts
  3  0x030  4               11  Number of Mechanical Start Failures
  4  =====  =                =  == General Errors Statistics (rev 1) ==
  4  0x008  4                0  Number of Reported Uncorrectable Errors
  4  0x010  4               22  Resets Between Cmd Acceptance and Completion
  5  =====  =                =  == Temperature Statistics (rev 1) ==
  5  0x008  1               48  Current Temperature

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error

Non-Raid drives

Western Digital Drives

Raid drives

WD RE4 (Gold?)

WDC WD1003FBYX-01Y7B1 (1TB)

smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Western Digital RE4
Device Model:     WDC WD1003FBYX-01Y7B1
Serial Number:    WD-WCAW36571293
LU WWN Device Id: 5 0014ee 25e700225
Firmware Version: 01.01V02
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Tue Oct 10 10:13:52 2017 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM level is:     254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x84)	Offline data collection activity
					was suspended by an interrupting command from host.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(16860) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 166) minutes.
Conveyance self-test routine
recommended polling time: 	 (   5) minutes.
SCT capabilities: 	       (0x303f)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR-K   200   200   051    -    0
  3 Spin_Up_Time            POS--K   174   170   021    -    4283
  4 Start_Stop_Count        -O--CK   100   100   000    -    37
  5 Reallocated_Sector_Ct   PO--CK   200   200   140    -    0
  7 Seek_Error_Rate         -OSR-K   200   200   000    -    0
  9 Power_On_Hours          -O--CK   065   065   000    -    25633
 10 Spin_Retry_Count        -O--CK   100   253   000    -    0
 11 Calibration_Retry_Count -O--CK   100   253   000    -    0
 12 Power_Cycle_Count       -O--CK   100   100   000    -    36
192 Power-Off_Retract_Count -O--CK   200   200   000    -    30
193 Load_Cycle_Count        -O--CK   200   200   000    -    6
194 Temperature_Celsius     -O---K   119   109   000    -    28
196 Reallocated_Event_Count -O--CK   200   200   000    -    0
197 Current_Pending_Sector  -O--CK   200   200   000    -    0
198 Offline_Uncorrectable   ----CK   200   200   000    -    0
199 UDMA_CRC_Error_Count    -O--CK   200   200   000    -    0
200 Multi_Zone_Error_Rate   ---R--   200   200   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      5  Comprehensive SMART error log
0x03       GPL     R/O      6  Ext. Comprehensive SMART error log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x08       GPL     R/O      2  Power Conditions log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  SATA NCQ Queued Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa0-0xa7  GPL,SL  VS      16  Device vendor specific log
0xa8-0xb5  GPL,SL  VS       1  Device vendor specific log
0xb6       GPL     VS       1  Device vendor specific log
0xb7       GPL,SL  VS       1  Device vendor specific log
0xbd       GPL,SL  VS       1  Device vendor specific log
0xc0       GPL,SL  VS       1  Device vendor specific log
0xc1       GPL     VS      24  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%     25579         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       258 (0x0102)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    28 Celsius
Power Cycle Min/Max Temperature:     27/30 Celsius
Lifetime    Min/Max Temperature:     27/38 Celsius
Under/Over Temperature Limit Count:   0/0

SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:      0/60 Celsius
Min/Max Temperature Limit:           -41/85 Celsius
Temperature History Size (Index):    478 (137)

Index    Estimated Time   Temperature Celsius
 108    2017-10-10 09:44    27  ********
 109    2017-10-10 09:45    28  *********
 ...    ..( 27 skipped).    ..  *********
 137    2017-10-10 10:13    28  *********

SCT Error Recovery Control:
           Read:     70 (7.0 seconds)
          Write:     70 (7.0 seconds)

Device Statistics (GP/SMART Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error
0x0002  2            0  R_ERR response for data FIS
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0005  2            0  R_ERR response for non-data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x0008  2            0  Device-to-host non-data FIS retries
0x0009  2           11  Transition from drive PhyRdy to drive PhyNRdy
0x000a  2            3  Device-to-host register FISes sent due to a COMRESET
0x000b  2            0  CRC errors within host-to-device FIS
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
0x8000  4      2152921  Vendor specific

WDC WD2003FYYS-02W0B0 2TB

smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Western Digital RE4
Device Model:     WDC WD2003FYYS-02W0B0
Serial Number:    WD-WMAY01652712
LU WWN Device Id: 5 0014ee 6565a5b8c
Firmware Version: 01.01D01
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Tue Oct 10 12:02:08 2017 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Disabled
APM level is:     254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x84)	Offline data collection activity
					was suspended by an interrupting command from host.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(28800) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 293) minutes.
Conveyance self-test routine
recommended polling time: 	 (   5) minutes.
SCT capabilities: 	       (0x303f)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR-K   200   200   051    -    0
  3 Spin_Up_Time            POS--K   253   253   021    -    8158
  4 Start_Stop_Count        -O--CK   100   100   000    -    17
  5 Reallocated_Sector_Ct   PO--CK   200   200   140    -    0
  7 Seek_Error_Rate         -OSR-K   200   200   000    -    0
  9 Power_On_Hours          -O--CK   060   060   000    -    29700
 10 Spin_Retry_Count        -O--CK   100   253   000    -    0
 11 Calibration_Retry_Count -O--CK   100   253   000    -    0
 12 Power_Cycle_Count       -O--CK   100   100   000    -    15
192 Power-Off_Retract_Count -O--CK   200   200   000    -    11
193 Load_Cycle_Count        -O--CK   200   200   000    -    5
194 Temperature_Celsius     -O---K   122   105   000    -    30
196 Reallocated_Event_Count -O--CK   200   200   000    -    0
197 Current_Pending_Sector  -O--CK   200   200   000    -    0
198 Offline_Uncorrectable   ----CK   200   200   000    -    0
199 UDMA_CRC_Error_Count    -O--CK   200   200   000    -    0
200 Multi_Zone_Error_Rate   ---R--   200   200   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      5  Comprehensive SMART error log
0x03       GPL     R/O      6  Ext. Comprehensive SMART error log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  SATA NCQ Queued Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa0-0xa7  GPL,SL  VS      16  Device vendor specific log
0xa8-0xb5  GPL,SL  VS       1  Device vendor specific log
0xb6       GPL     VS       1  Device vendor specific log
0xb7       GPL,SL  VS       1  Device vendor specific log
0xbd       GPL,SL  VS       1  Device vendor specific log
0xc0       GPL,SL  VS       1  Device vendor specific log
0xc1       GPL     VS      24  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%     29646         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       258 (0x0102)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    30 Celsius
Power Cycle Min/Max Temperature:     30/34 Celsius
Lifetime    Min/Max Temperature:     30/47 Celsius
Under/Over Temperature Limit Count:   0/0

SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:      0/60 Celsius
Min/Max Temperature Limit:           -41/85 Celsius
Temperature History Size (Index):    478 (463)

Index    Estimated Time   Temperature Celsius
 464    2017-10-10 04:05    30  ***********
 ...    ..(476 skipped).    ..  ***********
 463    2017-10-10 12:02    30  ***********

SCT Error Recovery Control:
           Read:     70 (7.0 seconds)
          Write:     70 (7.0 seconds)

Device Statistics (GP/SMART Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error

WD Scorpio Blue

WDC WD3200BEVS (2007?) 320 GB

smartctl 6.2 2013-11-07 r3856 [x86_64-linux-4.4.76-1-default] (SUSE RPM)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD3200BEVS-26VAT0
Serial Number:    WD-WXEY08TNC596
LU WWN Device Id: 5 0014ee 202491e9f
Firmware Version: 11.01A11
User Capacity:    320,072,933,376 bytes [320 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    5400 rpm
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 2.5, 1.5 Gb/s
Local Time is:    Mon Sep  4 17:45:19 2017 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Disabled
APM level is:     128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(10380) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 122) minutes.
Conveyance self-test routine
recommended polling time: 	 (   5) minutes.
SCT capabilities: 	       (0x303f)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR-K   200   200   051    -    0
  3 Spin_Up_Time            POS--K   188   186   021    -    1600
  4 Start_Stop_Count        -O--CK   087   087   000    -    13483
  5 Reallocated_Sector_Ct   PO--CK   200   200   140    -    0
  7 Seek_Error_Rate         -OSR-K   200   200   000    -    0
  9 Power_On_Hours          -O--CK   098   098   000    -    1680
 10 Spin_Retry_Count        PO--CK   100   100   051    -    0
 11 Calibration_Retry_Count -O--CK   100   100   000    -    0
 12 Power_Cycle_Count       -O--CK   094   094   000    -    6965
192 Power-Off_Retract_Count -O--CK   200   200   000    -    95
193 Load_Cycle_Count        -O--CK   196   196   000    -    14147
194 Temperature_Celsius     -O---K   098   095   000    -    49
196 Reallocated_Event_Count -O--CK   200   200   000    -    0
197 Current_Pending_Sector  -O--CK   200   200   000    -    1
198 Offline_Uncorrectable   ----CK   100   253   000    -    0
199 UDMA_CRC_Error_Count    -O--CK   200   200   000    -    0
200 Multi_Zone_Error_Rate   P--R--   100   253   051    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      5  Comprehensive SMART error log
0x03       GPL     R/O      6  Ext. Comprehensive SMART error log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  NCQ Command Error log
0x11       GPL     R/O      1  SATA Phy Event Counters
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa0-0xa7  GPL,SL  VS      16  Device vendor specific log
0xa8-0xb7  GPL,SL  VS       1  Device vendor specific log
0xc0       GPL,SL  VS       1  Device vendor specific log
0xc1       GPL     VS      24  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 3
	CR     = Command Register
	FEATR  = Features Register
	COUNT  = Count (was: Sector Count) Register
	LBA_48 = Upper bytes of LBA High/Mid/Low Registers ]  ATA-8
	LH     = LBA High (was: Cylinder High) Register    ]   LBA
	LM     = LBA Mid (was: Cylinder Low) Register      ] Register
	LL     = LBA Low (was: Sector Number) Register     ]
	DV     = Device (was: Device/Head) Register
	DC     = Device Control Register
	ER     = Error register
	ST     = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 3 [2] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 00 01 00 00 51 00 00 40 01 00 00

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  00 67 61 15 ce 00 00 00 00 00 00 00 00     00:00:00.000  NOP [Reserved subcommand] [OBS-ACS-2]
  00 28 20 00 e0 15 67 0c ce 61 00 00 00     00:00:51.248  NOP [Reserved subcommand] [OBS-ACS-2]
  04 66 2f 15 ce 00 20 00 e0 80 00 00 00     00:23:49.095  [RESERVED]
  00 18 80 00 e0 15 67 04 c2 60 00 00 00     00:00:04.097  NOP [Reserved subcommand] [OBS-ACS-2]

Error 2 [1] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 00 01 00 00 51 00 00 40 01 00 00

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  00 67 60 15 c2 00 00 00 00 00 00 00 04     00:00:00.000  NOP [Reserved subcommand] [OBS-ACS-2]
  00 01 00 00 10 15 67 00 c2 2f 00 00 00     00:00:57.368  NOP [Abort queued commands]
  04 63 60 15 b6 00 f8 00 e0 80 00 00 04     00:23:42.947  [RESERVED]
  00 e8 20 00 e0 15 25 0c b6 61 00 00 00     00:00:49.392  NOP [Reserved subcommand] [OBS-ACS-2]

Error 1 [0] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 00 01 00 00 51 00 00 40 01 00 00

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  00 63 60 15 b6 00 00 00 00 00 00 00 04     00:00:00.000  NOP [Reserved subcommand] [OBS-ACS-2]
  00 f0 20 00 c0 15 63 04 b6 60 00 00 00     00:00:57.592  NOP [Reserved subcommand] [OBS-ACS-2]
  0c 25 61 15 b6 00 e8 00 e0 20 00 00 0d     00:23:42.885  [RESERVED]
  00 d8 03 00 28 15 1d 0d b6 60 00 00 00     00:00:08.416  NOP [Reserved subcommand] [OBS-ACS-2]

SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  2
SCT Version (vendor specific):       258 (0x0102)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    49 Celsius
Power Cycle Min/Max Temperature:     37/49 Celsius
Lifetime    Min/Max Temperature:     37/52 Celsius
Under/Over Temperature Limit Count:   0/0
SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:      0/60 Celsius
Min/Max Temperature Limit:            1/85 Celsius
Temperature History Size (Index):    128 (124)

Index    Estimated Time   Temperature Celsius
 122    2017-09-04 17:43    48  *****************************
 123    2017-09-04 17:44    48  *****************************
 124    2017-09-04 17:45    49  ******************************

SCT Error Recovery Control:
           Read: Disabled
          Write: Disabled

Device Statistics (GP Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error
0x0002  2            0  R_ERR response for data FIS
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0005  2            0  R_ERR response for non-data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x000a  2            4  Device-to-host register FISes sent due to a COMRESET
0x8000  4         1213  Vendor specific