Introduction

From Linux Raid Wiki
Revision as of 18:01, 2 October 2006 by DavidGreaves (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Contents

Introduction

This HOWTO describes the "new-style" RAID present in the 2.4 and 2.6 kernel series only. It does not describe the "old-style" RAID functionality present in 2.0 and 2.2 kernels.

The home site for this HOWTO is http://unthought.net/Software- RAID.HOWTO/, where updated versions appear first. The howto was originally written by Jakob OEstergaard based on a large number of emails between the author and Ingo Molnar (mingo@chiara.csoma.elte.hu) -- one of the RAID developers --, the linux-raid mailing list (linux- raid@vger.kernel.org) and various other people. Emilio Bueso (bueso@vives.org) co-wrote the 1.0 version.

If you want to use the new-style RAID with 2.0 or 2.2 kernels, you should get a patch for your kernel, from http://people.redhat.com/mingo/ The standard 2.2 kernels does not have direct support for the new-style RAID described in this HOWTO. Therefore these patches are needed. The old-style RAID support in standard 2.0 and 2.2 kernels is buggy and lacks several important features present in the new-style RAID software.

Some of the information in this HOWTO may seem trivial, if you know RAID all ready. Just skip those parts.


Disclaimer

The mandatory disclaimer:

All information herein is presented "as-is", with no warranties expressed nor implied. If you lose all your data, your job, get hit by a truck, whatever, it's not my fault, nor the developers'. Be aware, that you use the RAID software and this information at your own risk! There is no guarantee whatsoever, that any of the software, or this information, is in any way correct, nor suited for any use whatsoever. Back up all your data before experimenting with this. Better safe than sorry.


What is RAID?

In 1987, the University of California Berkeley, published an article entitled A Case for Redundant Arrays of Inexpensive Disks (RAID). This article described various types of disk arrays, referred to by the acronym RAID. The basic idea of RAID was to combine multiple small, independent disk drives into an array of disk drives which yields performance exceeding that of a Single Large Expensive Drive (SLED). Additionally, this array of drives appears to the computer as a single logical storage unit or drive.

The Mean Time Between Failure (MTBF) of the array will be equal to the MTBF of an individual drive, divided by the number of drives in the array. Because of this, the MTBF of an array of drives would be too low for many application requirements. However, disk arrays can be made fault-tolerant by redundantly storing information in various ways.

Five types of array architectures, RAID-1 through RAID-5, were defined by the Berkeley paper, each providing disk fault-tolerance and each offering different trade-offs in features and performance. In addition to these five redundant array architectures, it has become popular to refer to a non-redundant array of disk drives as a RAID-0 array.

Today some of the original RAID levels (namely level 2 and 3) are only used in very specialized systems (and in fact not even supported by the Linux Software RAID drivers). Another level, "linear" has emerged, and especially RAID level 0 is often combined with RAID level 1.


Terms

In this HOWTO the word "RAID" means "Linux Software RAID". This HOWTO does not treat any aspects of Hardware RAID. Furthermore, it does not treat any aspects of Software RAID in other operating system kernels.

When describing RAID setups, it is useful to refer to the number of disks and their sizes. At all times the letter N is used to denote the number of active disks in the array (not counting spare-disks). The letter S is the size of the smallest drive in the array, unless otherwise mentioned. The letter P is used as the performance of one disk in the array, in MB/s. When used, we assume that the disks are equally fast, which may not always be true in real-world scenarios.

Note that the words "device" and "disk" are supposed to mean about the same thing. Usually the devices that are used to build a RAID device are partitions on disks, not necessarily entire disks. But combining several partitions on one disk usually does not make sense, so the words devices and disks just mean "partitions on different disks".


The RAID levels

Here's a short description of what is supported in the Linux RAID drivers. Some of this information is absolutely basic RAID info, but I've added a few notices about what's special in the Linux implementation of the levels. You can safely skip this section if you know RAID already.

The current RAID drivers in Linux supports the following levels:

 o  Linear mode
    o  Two or more disks are combined into one physical device. The
       disks are "appended" to each other, so writing linearly to the
       RAID device will fill up disk 0 first, then disk 1 and so on.
       The disks does not have to be of the same size. In fact, size
       doesn't matter at all here :)
    o  There is no redundancy in this level. If one disk crashes you
       will most probably lose all your data.  You can however be lucky
       to recover some data, since the filesystem will just be missing
       one large consecutive chunk of data.
    o  The read and write performance will not increase for single
       reads/writes. But if several users use the device, you may be
       lucky that one user effectively is using the first disk, and the
       other user is accessing files which happen to reside on the
       second disk. If that happens, you will see a performance gain.
 o  RAID-0
    o  Also called "stripe" mode. The devices should (but need not)
       have the same size. Operations on the array will be split on the
       devices; for example, a large write could be split up as 4 kB to
       disk 0, 4 kB to disk 1, 4 kB to disk 2, then 4 kB to disk 0
       again, and so on. If one device is much larger than the other
       devices, that extra space is still utilized in the RAID device,
       but you will be accessing this larger disk alone, during writes
       in the high end of your RAID device. This of course hurts
       performance.
    o  Like linear, there is no redundancy in this level either. Unlike
       linear mode, you will not be able to rescue any data if a drive
       fails. If you remove a drive from a RAID-0 set, the RAID device
       will not just miss one consecutive block of data, it will be
       filled with small holes all over the device. e2fsck or other
       filesystem recovery tools will probably not be able to recover
       much from such a device.
    o  The read and write performance will increase, because reads and
       writes are done in parallel on the devices. This is usually the
       main reason for running RAID-0. If the busses to the disks are
       fast enough, you can get very close to N*P MB/sec.
 o  RAID-1
    o  This is the first mode which actually has redundancy. RAID-1 can
       be used on two or more disks with zero or more spare-disks. This
       mode maintains an exact mirror of the information on one disk on
       the other disk(s). Of Course, the disks must be of equal size.
       If one disk is larger than another, your RAID device will be the
       size of the smallest disk.
    o  If up to N-1 disks are removed (or crashes), all data are still
       intact. If there are spare disks available, and if the system
       (eg. SCSI drivers or IDE chipset etc.) survived the crash,
       reconstruction of the mirror will immediately begin on one of
       the spare disks, after detection of the drive fault.
    o  Write performance is often worse than on a single device,
       because identical copies of the data written must be sent to
       every disk in the array. With large RAID-1 arrays this can be a
       real problem, as you may saturate the PCI bus with these extra
       copies. This is in fact one of the very few places where
       Hardware RAID solutions can have an edge over Software solutions
       - if you use a hardware RAID card, the extra write copies of the
       data will not have to go over the PCI bus, since it is the RAID
       controller that will generate the extra copy. Read performance
       is good, especially if you have multiple readers or seek-
       intensive workloads. The RAID code employs a rather good read-
       balancing algorithm, that will simply let the disk whose heads
       are closest to the wanted disk position perform the read
       operation. Since seek operations are relatively expensive on
       modern disks (a seek time of 6 ms equals a read of 123 kB at 20
       MB/sec), picking the disk that will have the shortest seek time
       does actually give a noticeable performance improvement.
 o  RAID-4
    o  This RAID level is not used very often. It can be used on three
       or more disks. Instead of completely mirroring the information,
       it keeps parity information on one drive, and writes data to the
       other disks in a RAID-0 like way.  Because one disk is reserved
       for parity information, the size of the array will be (N-1)*S,
       where S is the size of the smallest drive in the array. As in
       RAID-1, the disks should either be of equal size, or you will
       just have to accept that the S in the (N-1)*S formula above will
       be the size of the smallest drive in the array.
    o  If one drive fails, the parity information can be used to
       reconstruct all data.  If two drives fail, all data is lost.
    o  The reason this level is not more frequently used, is because
       the parity information is kept on one drive. This information
       must be updated every time one of the other disks are written
       to. Thus, the parity disk will become a bottleneck, if it is not
       a lot faster than the other disks.  However, if you just happen
       to have a lot of slow disks and a very fast one, this RAID level
       can be very useful.
 o  RAID-5
    o  This is perhaps the most useful RAID mode when one wishes to
       combine a larger number of physical disks, and still maintain
       some redundancy. RAID-5 can be used on three or more disks, with
       zero or more spare-disks. The resulting RAID-5 device size will
       be (N-1)*S, just like RAID-4. The big difference between RAID-5
       and -4 is, that the parity information is distributed evenly
       among the participating drives, avoiding the bottleneck problem
       in RAID-4.
    o  If one of the disks fail, all data are still intact, thanks to
       the parity information. If spare disks are available,
       reconstruction will begin immediately after the device failure.
       If two disks fail simultaneously, all data are lost. RAID-5 can
       survive one disk failure, but not two or more.
    o  Both read and write performance usually increase, but can be
       hard to predict how much. Reads are similar to RAID-0 reads,
       writes can be either rather expensive (requiring read-in prior
       to write, in order to be able to calculate the correct parity
       information), or similar to RAID-1 writes. The write efficiency
       depends heavily on the amount of memory in the machine, and the
       usage pattern of the array. Heavily scattered writes are bound
       to be more expensive.


Requirements

This HOWTO assumes you are using Linux 2.4 or later. However, it is possible to use Software RAID in late 2.2.x or 2.0.x Linux kernels with a matching RAID patch and the 0.90 version of the raidtools. Both the patches and the tools can be found at http://people.redhat.com/mingo/. The RAID patch, the raidtools package, and the kernel should all match as close as possible. At times it can be necessary to use older kernels if raid patches are not available for the latest kernel.

If you use and recent GNU/Linux distribution based on the 2.4 kernel or later, your system most likely already has a matching version of the raidtools for your kernel.